412 664

Cited 0 times in

개질 고분자 이식편을 이용한 관상동맥용 스텐트 그라프트의 개발

Other Titles
 Development of New Coronary Stent-Grafts using Surface-Modified Polymers 
Authors
 최동훈  ;  고영국  ;  김성순  ;  장양수  ;  정광회  ;  박기동  ;  정동준  ;  김현주  ;  김세훈 
Citation
 KOREAN CIRCULATION JOURNAL, Vol.33(9) : 832-846, 2003 
Journal Title
KOREAN CIRCULATION JOURNAL(순환기)
ISSN
 1738-5520 
Issue Date
2003
MeSH
Coronary disease;Stents;Polymers
Keywords
Coronary disease;Stents;Polymers
Abstract
Background and Objectives:The purpose of this study was to develop a new type of coronary stent-graft, using surface modification of polymeric synthetic graft materials, to improve biocompatibility.
Materials and Methods:Three different polymers, Dacron, GoreTex and Teflon were tested. During the surface-modification process, hydroxybutyl acrylate (HBA) choline, an excellent blood-compatible phospholipid, was stably grafted onto the polymer surface. The optimal conditions for maximizing the amount of HBA choline grafted onto the polymeric surface were determined by quantitative analysis. The surface-modified polymers were then tested for their biocompatibility using an in vitro platelet adhesion test. Thereafter, stent-grafts were constructed with each of three different types of surface-modified polymer and implanted in porcine coronary arteries to compare their biocompatibility in vivo.
Results:In the platelet adhesion test, all the surface-modified polymers showed better biocompatibility than the control polymers. The in vitro biocompatibility correlated positively with the increasing quantity of grafted HBA choline. In the animal experiment, the surface-modified Teflon stent-graft showed the best biocompatibility. Whereas, all pigs implanted with the modified Dacron and GoreTex stent-grafts died within 48 hours of the implantation, five out of the six pigs with the Teflon stent-grafts remained alive at after the 4th week. In four of the five surviving pigs, angiography, intravascular ultrasound (IVUS) and histological evaluations demonstrated the patency of the stent-grafts, with a uniform neointima formation covering the entire stent-graft, without stent thrombosis or chronic inflammatory cells.
Conclusion:The surface-modified Teflon coronary stent-grafts showed good in vitro and in vivo biocompatibility. Further animal and clinical studies will be required to validate the efficacy of the surface-modified polymer stent-grafts.
Files in This Item:
T200304807.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Pathology (병리학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Se Hoon(김세훈) ORCID logo https://orcid.org/0000-0001-7516-7372
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/113940
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links