420 599

Cited 0 times in

인공수정체의 종류에 따른 예측굴절력과 실제굴절력의 차이에 대한 연구

DC Field Value Language
dc.contributor.author서경률-
dc.contributor.author이성준-
dc.date.accessioned2015-07-15T16:34:17Z-
dc.date.available2015-07-15T16:34:17Z-
dc.date.issued2003-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/113165-
dc.description.abstractPurpose: To evaluate the difference between the predicted and actual refraction among the intraocular lenses having different materials and shapes of optic and haptic. Methods: We retrospectively analyzed the cases of 680 eyes with normal range of axial length (21-26mm),which underwent phacoemulsification and posterior chamber 10L implantation, and had at least 2 months fo11ow up period, divided by 4 groups according to the types of 10L used. Results: Mean age of the subjects was 68.9±10.8 years with 197 eyes (29%) of male and 483 eyes (71%)of female. The difference between the predicted and 2 month-postoperative refraction was +0.01 (SI40NB),-0.01 (LI61U), -0.45 (C3lUB), +0.05 (MA60BM) diopters, respectively. C31UB group represented the myopic shift of -0.45D range and other groups showed no statistically significant difference. Conclusions: There was no effect of optic materials on the acquisition of goal diopter, MA60BM, SI40NB, L161U showed high accuracy of predictiveness. The cause of myopic shift represented in C3lUB group might be the differences of the haptic material, optic-haptic junction, or overall diameter.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHGoal diopter-
dc.subject.MESHHaptic material-
dc.subject.MESHIntraocular lens-
dc.subject.MESHOptic material-
dc.title인공수정체의 종류에 따른 예측굴절력과 실제굴절력의 차이에 대한 연구-
dc.title.alternativeEvaluation of the Difference between the Predicted and Actual Refraction Among Different Types of Intraocular Lenses-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor김상훈-
dc.contributor.googleauthor이성준-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor박혜성-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02871-
dc.contributor.localIdA01870-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordGoal diopter-
dc.subject.keywordHaptic material-
dc.subject.keywordIntraocular lens-
dc.subject.keywordOptic material-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameLee, Sung Jun-
dc.contributor.affiliatedAuthorLee, Sung Jun-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.rights.accessRightsfree-
dc.citation.volume44-
dc.citation.number5-
dc.citation.startPage1066-
dc.citation.endPage1071-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.44(5) : 1066-1071, 2003-
dc.identifier.rimsid54177-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.