554 612

Cited 0 times in

디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환

DC Field Value Language
dc.contributor.author김경호-
dc.contributor.author최광철-
dc.date.accessioned2015-07-14T17:21:53Z-
dc.date.available2015-07-14T17:21:53Z-
dc.date.issued2004-
dc.identifier.issn2234-7518-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/112733-
dc.description.abstractAs computer programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered is the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence, we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows: The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under 16.4mm, barrel distortion was found and when tele imaging, with a focal length of over 16.4mm, pincushion distortion was found. The minimal digital camera setting was 2272×1704 pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result, when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm, the pixel image size over 2272×1704, and the compression ratio over normal (1/8).-
dc.description.statementOfResponsibilityopen-
dc.format.extent448~457-
dc.relation.isPartOfKOREAN JOURNAL OF ORTHODONTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환-
dc.title.alternativeDigital imaging of film-based cephalograms using a digital camera-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Orthodontics (교정과학)-
dc.contributor.googleauthor디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00309-
dc.contributor.localIdA04040-
dc.relation.journalcodeJ02087-
dc.identifier.eissn2005-372X-
dc.subject.keywordDigital camera-
dc.subject.keywordFilm-based cephalogram-
dc.subject.keywordDigital imaging-
dc.subject.keywordError of landmark identification-
dc.contributor.alternativeNameKim, Kyung Ho-
dc.contributor.alternativeNameChoy, Kwang Chul-
dc.contributor.affiliatedAuthorKim, Kyung Ho-
dc.contributor.affiliatedAuthorChoy, Kwang Chul-
dc.rights.accessRightsfree-
dc.citation.volume34-
dc.citation.number5-
dc.citation.startPage448-
dc.citation.endPage457-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF ORTHODONTICS, Vol.34(5) : 448-457, 2004-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.