279 495

Cited 0 times in

치수압이 상아질 접착제의 미세전단 결합강도에 미치는 영향에 관한 In vitro 연구

DC Field Value Language
dc.contributor.author박성호-
dc.date.accessioned2015-07-14T17:21:39Z-
dc.date.available2015-07-14T17:21:39Z-
dc.date.issued2004-
dc.identifier.issn1225-0864-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/112725-
dc.description.abstractThe aim of this study was to measure and compare the micro shear bond strengths of the following dentin bonding systems to the dentin surfaces under simulated pulpal pressure; All Bond 2®, Second®, AdheSE®, Adper Prompt L-Pop®. The occlusal surfaces of 180 extracted human molars were prepared so the dentin bonding surfaces could be exposed. The teeth were randomly assigned to 3 equal groups of 60 each and subdivided. The dentin surfaces were treated with the above mentioned bonding system and resin composite cylinders were built up under a simulated pulpal pressure when saline (Group II) or diluted bovine serum (Group III) was used as the pulpal fluid. As a control, the same procedures were performed in the dried dentin surfaces (Group I). After one day of storage in water, the micro shear bond strengths were measured using an EZ tester. Group II and III showed significantly lower shear bond strength than Group I statistically (p < 0.05). SEbond® and AdheSE® showed no difference among the different dentin condition. In the Adper Prompt L-Pop®, a simulated pulpal pressure were applied to the specimens using diluted bovine serum, which showed a higher strength than the specimens in which saline was used (p < 0.05).-
dc.description.statementOfResponsibilityopen-
dc.format.extent339~345-
dc.relation.isPartOfJournal of Korean Academy of Operative Dentistry (대한치과보존학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title치수압이 상아질 접착제의 미세전단 결합강도에 미치는 영향에 관한 In vitro 연구-
dc.title.alternativeMicro-shear bond strength to dentin under simulated pulpal pressure-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학)-
dc.contributor.googleauthor송윤정-
dc.contributor.googleauthor박성호-
dc.identifier.doi10.5395/JKACD.2004.29.4.339-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01514-
dc.relation.journalcodeJ01488-
dc.subject.keywordMicro-shear bond strength-
dc.subject.keywordPulpal pressure-
dc.contributor.alternativeNamePark, Sung Ho-
dc.contributor.affiliatedAuthorPark, Sung Ho-
dc.rights.accessRightsfree-
dc.citation.volume29-
dc.citation.number4-
dc.citation.startPage339-
dc.citation.endPage345-
dc.identifier.bibliographicCitationJournal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.29(4) : 339-345, 2004-
dc.identifier.rimsid42644-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.