Cited 0 times in
Duct- Occlud를 이용한 동맥관의 경피적 폐쇄술의 중간 추적 관찰 결과 및 시술과 연관된 문제점
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김유리아 | - |
dc.contributor.author | 박영환 | - |
dc.contributor.author | 설준희 | - |
dc.contributor.author | 이승규 | - |
dc.contributor.author | 이종균 | - |
dc.contributor.author | 조범구 | - |
dc.contributor.author | 최재영 | - |
dc.date.accessioned | 2015-07-14T17:14:11Z | - |
dc.date.available | 2015-07-14T17:14:11Z | - |
dc.date.issued | 2004 | - |
dc.identifier.issn | 1738-1061 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/112477 | - |
dc.description.abstract | Purpose : We will present our mid-term result of transcatheter closure of PDA with Duct-Occlud device(pfm. AG. Germany) after 12 months follow up and report the problems during the procedure. Methods : In total 154 patients, the Duct-Occlud devices were inserted in our institute from March, 1996 to August, 2002. Three types of Duct-Occlud device, i.e standard, reinforced, reinforced reverse cone coil were used. Echocardiographic examination was performed at 1, 6, 12 months after procedure. Results : The echocardiographic closure rate was 96% after 12 months. The rates of residual shunt in the standard coil, the reverse cone coil, and the reinforced reverse cone group were 8%, 4% and 3% respectively. In PDA with diameter less than 4 mm, the closure rate was up to 98% while in large PDA with more than 4 mm, it was 72% after 12 months. Embolization of the inserted coils had occurred in 5 cases with successful retrieval using snare catheter. The rupture of the core wire during the procedure and distortion of the original coil shape had occurred in 4 cases. Conclusion : The transcatheter occlusion with Duct Occlud is safe and effective method for small to moderate sized PDA less than 4 mm. The minimum diameter of the PDA seems to be the predictor of residual shunt. Further refinement of the device to overcome the procedure-related problems seems to be needed. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 36~43 | - |
dc.language | Korean | - |
dc.publisher | 대한소아과학회 | - |
dc.relation.isPartOf | Korean Journal of Pediatrics | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Duct- Occlud를 이용한 동맥관의 경피적 폐쇄술의 중간 추적 관찰 결과 및 시술과 연관된 문제점 | - |
dc.title.alternative | Mid-term Result of the Transcatheter Occlusion of Patent Ductus Arteriosus with Duct-Occlud Device and Procedure-Related Problems | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Thoracic & Cardiovascular Surgery (흉부외과학) | - |
dc.contributor.googleauthor | 김유리아 | - |
dc.contributor.googleauthor | 최재영 | - |
dc.contributor.googleauthor | 조범구 | - |
dc.contributor.googleauthor | 박영환 | - |
dc.contributor.googleauthor | 이승규 | - |
dc.contributor.googleauthor | 설준희 | - |
dc.contributor.googleauthor | 이종균 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.relation.journalcode | J02100 | - |
dc.identifier.eissn | 2092-7258 | - |
dc.subject.keyword | Patent ductus arterisus | - |
dc.subject.keyword | Duct-Occlud | - |
dc.subject.keyword | Transcatheter occlusion | - |
dc.contributor.alternativeName | Kim, Yuria | - |
dc.contributor.alternativeName | Park, Young Hwan | - |
dc.contributor.alternativeName | Sul, Jun Hui | - |
dc.contributor.alternativeName | Lee, Sung Kyu | - |
dc.contributor.alternativeName | Lee, Jong Kyun | - |
dc.contributor.alternativeName | Cho, Bum Koo | - |
dc.contributor.alternativeName | Choi, Jae Young | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 47 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 36 | - |
dc.citation.endPage | 43 | - |
dc.identifier.bibliographicCitation | Korean Journal of Pediatrics, Vol.47(1) : 36-43, 2004 | - |
dc.identifier.rimsid | 56200 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.