310 488

Cited 48 times in

Evaluation of Computer-Based Volume Measurement and Porous Polyethylene Channel Implants in Reconstruction of Large Orbital Wall Fractures

DC Field Value Language
dc.contributor.author이상열-
dc.date.accessioned2015-06-10T12:25:49Z-
dc.date.available2015-06-10T12:25:49Z-
dc.date.issued2006-
dc.identifier.issn0146-0404-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/109786-
dc.description.abstractPURPOSE: To describe the use of computer-based orbital volume measurement as a predictor of late enophthalmos, and to assess the effectiveness of the MedPor (Porex Surgical Products Group, Newnan, GA) porous polyethylene channel implant to restore orbital volume in repairing large orbital wall fractures. METHODS: Sixteen patients with unilateral large orbital fractures were included. Computed tomographic (CT) scans were used to obtain computer-based orbital volume measurement to predict the likelihood of late enophthalmos and to assess the change in orbital volume before and after surgery. The effectiveness of a channel implant was evaluated by the orbital volume and postoperative exophthalmetric measurement. RESULTS: The average time interval between injury and surgery was 17.4 +/- 10 days, and the mean follow-up was 9 months. The orbital volume of the injured orbit was significantly increased (mean, 4.22 +/- 2.61 cm2) compared with the unaffected orbit before surgery (t = 3.046, P = 0.005). There was not a significant difference in orbital volume between the two orbits after orbital reconstruction (t = 0.069, P = 0.945). The orbital volume change after reconstructive surgery was significantly positively correlated with the decrease of enophthalmos (r = 0.715, P = 0.001; enophthalmos [E] = 0.72; volume increment [V] = 0.06). To resolve 2 mm enophthalmos, more than 2.9 cm3 orbital volume augmentation is recommended for early reconstructive surgery. Postoperative CT scan showed most of the channel implants to be well positioned. CONCLUSIONS: Computer-based orbital volume measurement from a CT scan is useful in the posttraumatic evaluation of orbital fractures, and it can help predict the degree of late enophthalmos that can be expected. Orbital reconstruction with the MedPor channel implant (Porex Surgical Products Group), when indicated, is recommended, especially for large orbital wall fractures.-
dc.description.statementOfResponsibilityopen-
dc.format.extent509~513-
dc.relation.isPartOfINVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHBiocompatible Materials*-
dc.subject.MESHBody Weights and Measures-
dc.subject.MESHEnophthalmos/diagnostic imaging*-
dc.subject.MESHFemale-
dc.subject.MESHFollow-Up Studies-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOphthalmologic Surgical Procedures-
dc.subject.MESHOrbit/diagnostic imaging*-
dc.subject.MESHOrbital Fractures/diagnostic imaging-
dc.subject.MESHOrbital Fractures/surgery*-
dc.subject.MESHPolyethylenes*-
dc.subject.MESHPorosity-
dc.subject.MESHPostoperative Complications/diagnostic imaging*-
dc.subject.MESHProstheses and Implants*-
dc.subject.MESHProsthesis Implantation-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHTomography, X-Ray Computed-
dc.titleEvaluation of Computer-Based Volume Measurement and Porous Polyethylene Channel Implants in Reconstruction of Large Orbital Wall Fractures-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorJuan Ye-
dc.contributor.googleauthorKoung Hoon Kook-
dc.contributor.googleauthorSang Yeul Lee-
dc.identifier.doi10.1167/iovs.05-0816-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02819-
dc.relation.journalcodeJ01187-
dc.identifier.eissn1552-5783-
dc.identifier.pmid16431943-
dc.contributor.alternativeNameLee, Sang Yeul-
dc.contributor.affiliatedAuthorLee, Sang Yeul-
dc.rights.accessRightsfree-
dc.citation.volume47-
dc.citation.number2-
dc.citation.startPage509-
dc.citation.endPage513-
dc.identifier.bibliographicCitationINVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, Vol.47(2) : 509-513, 2006-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.