2019 783

Cited 0 times in

혈액 투석을 위한 내동정맥루 감시를 위한 투석관 내 혈류량 측정: 경향 분석

Other Titles
 Flow Measurement in the Hemodialysis Vascular Conduit for Surveillance of Internal Arteriovenous Fistula: A Trend Analysis 
Authors
 이종훈  ;  윤수영  ;  조현경  ;  송순영  ;  양성자  ;  안형준  ;  조희은  ;  김유선  ;  박기일 
Citation
 JOURNAL OF THE KOREAN SURGICAL SOCIETY , Vol.71(2) : 139-144, 2006 
Journal Title
JOURNAL OF THE KOREAN SURGICAL SOCIETY (대한외과학회지)
ISSN
 1226-0053 
Issue Date
2006
Keywords
Pressure measurement ; Bernoulli’s theory ; Vascular stenosis ; 압력 측정 ; 베르누이 정리 ; 혈관 협착
Abstract
Purpose: We have already reported on a new method to calculate the intra-vascular conduit flow rate based on Bernoulli's theory for maintaining surveillance of the arteriovenous fistula (AVF) function. To assess the clinical validity of our methods, we examined a trend analysis on the calculated flow rate in hemodialysis vascular conduits.
Methods: From a total of 27 cases of native AVFs that were at least 3 months after construction, we measured the AVF flow rate (QD) with Doppler ultrasonography first. When QD was below 600 ml/min, a fistulogram was taken. The intra- vascular conduit static pressure (ps) was measured, and the flow rate (Qa) was calculated every month with using the mean arterial pressure. The patients with a decreased Qa of more than 10% over 3 months were referred for a diagnostic fistulogram.
Results: Twenty-seven AVFs were studied after 29.5⁑28.5 (4∼120) months of operation. The mean QD was 980.6⁑501.6 (144∼2,230) ml/min. In 6 patients who showed a QD less than 600 ml/min, 4 pathologic lesions were found on the diagnostic fistulogram: juxta-anastomosis stenosis (n=3) and a draining venous stenosis (n=1). Three patients who showed a Qa decrement were confirmed as having a draining venous stenosis. However, any unpredictable thrombosis with proximal stenosis (n=2) couldn't be detected.
Conclusion: Qa represents the narrowing of the draining vein of an internal AVF. However, arterial or venous narrowing that is proximal to the arterial puncture site couldn't be detected with the calculated intra-conduit flow rate. The development of new methods that can detect proximal vascular stenosis and that can be used in combination with our method is anticipated in the near future.
Files in This Item:
T200600644.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Yu Seun(김유선) ORCID logo https://orcid.org/0000-0002-5105-1567
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/109532
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links