0 451

Cited 183 times in

Simultaneous determination of benzophenone-type UV filters in water and soil by gas chromatography–mass spectrometry

Authors
 Hee-Kyung Jeon  ;  Yong Chung  ;  Jae-Chun Ryu 
Citation
 JOURNAL OF CHROMATOGRAPHY A, Vol.1131(1-2) : 192-202, 2006 
Journal Title
JOURNAL OF CHROMATOGRAPHY A
ISSN
 0021-9673 
Issue Date
2006
MeSH
Acetamides ; Benzophenones/analysis* ; Benzophenones/chemistry ; Filtration ; Fluoroacetates ; Gas Chromatography-Mass Spectrometry/methods* ; Geography ; Korea ; Molecular Structure ; Soil/analysis* ; Sunscreening Agents/analysis* ; Sunscreening Agents/chemistry ; Trifluoroacetic Acid/analysis ; Trifluoroacetic Acid/chemistry ; Trimethylsilyl Compounds/analysis ; Trimethylsilyl Compounds/chemistry ; Ultraviolet Rays ; Water/analysis* ; Water/chemistry
Keywords
Benzophenone (BP) ; UV filters ; Water ; Soil ; Gas chromatography–mass spectrometry (GC–MS)
Abstract
A novel method has been developed to simultaneously determine and quantify seven organic UV filters employing liquid (solid)–liquid extraction, derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) and gas chromatography with mass spectrometric detection in various environmental matrices. The UV filters determined were: benzophenone (BP), benzhydrol (BH), 4-hydroxybenzophenone (HBP), 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2′-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxylbenzophenone (THB). Under optimal conditions, the analysis required 23 min and good linearity over the range of 10–2500 ng/L in water and 100–25000 ng/kg in soil for each UV filter obtained. The high recovery (62–114% and 60–125% for water and soil samples, respectively) and the low RSD values (less than 13.9 and 17.2% for water and soil samples, respectively) indicated the high performance of this method. The method detection limits (MDLs) were relatively low, ranging from 5 to 100 ng/L or kg and quantification limits ranged between 25 and 500 ng/L or kg for all test compounds. This validated method was applied in the analysis of seven BP-type UV filters collecting water and soil samples in Korea, between April and May 2003. The overall concentration of UV filters in the soil sample (500–18380 ng/kg) was highly distributed in water sample (27–204 ng/L). The established method was successfully applied to monitor the residue measurement of the BP-type UV filters in environmental water and soil samples.
Full Text
http://www.sciencedirect.com/science/article/pii/S0021967306013823
DOI
10.1016/j.chroma.2006.07.036
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Preventive Medicine (예방의학교실) > 1. Journal Papers
Yonsei Authors
Chung, Yong(정용)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/108832
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links