252 709

Cited 0 times in

수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향

DC Field Value Language
dc.contributor.author김의성-
dc.date.accessioned2015-06-10T11:53:02Z-
dc.date.available2015-06-10T11:53:02Z-
dc.date.issued2006-
dc.identifier.issn1225-0864-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/108794-
dc.description.abstractThere are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{®}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{®}$ (SybronEndo. Orange, CA) , Hero $642^{®}$ (Micro-mega, Besancon, France), Hero $Shaper^{®}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn’’t have any effect on the time of file fracture. Among the files, $Profile^{®}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.-
dc.description.statementOfResponsibilityopen-
dc.format.extent96~102-
dc.relation.isPartOfJournal of Korean Academy of Operative Dentistry (대한치과보존학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향-
dc.title.alternativeCompartative study on morphology of cross-section and cyclic fatigue test with different rotary NiTi files and handling methods-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학)-
dc.contributor.googleauthor김재관-
dc.contributor.googleauthor금기연-
dc.contributor.googleauthor김의성-
dc.identifier.doi10.5395/JKACD.2006.31.2.096-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00833-
dc.relation.journalcodeJ01488-
dc.subject.keywordFatigue fracture-
dc.subject.keywordCross-sectional area-
dc.subject.keywordPecking motion-
dc.subject.keywordPecking distance-
dc.contributor.alternativeNameKim, Eui Seong-
dc.contributor.affiliatedAuthorKim, Eui Seong-
dc.rights.accessRightsfree-
dc.citation.volume31-
dc.citation.number2-
dc.citation.startPage96-
dc.citation.endPage102-
dc.identifier.bibliographicCitationJournal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.31(2) : 96-102, 2006-
dc.identifier.rimsid57706-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.