0 461

Cited 34 times in

Comparison of higher order aberrations in eyes with aspherical or spherical intraocular lenses

Authors
 SW Kim  ;  H Ahn  ;  EK Kim  ;  T-i Kim 
Citation
 EYE, Vol.22(12) : 1493-1498, 2008 
Journal Title
EYE
ISSN
 0950-222X 
Issue Date
2008
MeSH
Cataract/physiopathology* ; Contrast Sensitivity/physiology* ; Double-Blind Method ; Female ; Humans ; Lenses, Intraocular* ; Male ; Middle Aged ; Phacoemulsification ; Postoperative Complications/physiopathology* ; Prosthesis Design ; Refractive Errors/physiopathology* ; Visual Acuity/physiology
Keywords
aspheric IOL ; constrast sensitivity ; ocular aberration ; Tecnis ZA 9003
Abstract
PURPOSE: To compare ocular, internal, corneal aberrations, and contrast sensitivity in patients implanted with aspheric or spherical intraocular lenses (IOLs).

METHODS: Total, corneal, and internal aberrations were measured using ray-tracing technology in 23 eyes implanted with aspheric (Tecnis ZA9003) IOLs, and in 25 eyes implanted with spherical (AcrySof SA60AT) IOLs. Spherical aberration (SA), coma, trefoil, and RMS of higher order aberrations (HOAs) were analysed for 4.0 and 6.0 mm optical zones. Best-corrected visual acuities (BCVAs), contrast sensitivity under photopic and mesopic conditions, and modulation transfer function (MTF) were evaluated to compare visual performances.

RESULTS: The mean internal SA was -0.06/-0.35 microm in the aspheric IOL group and 0.04/0.17 microm in the spherical IOL group (at 4 mm/6 mm pupil). Total SA was near to zero in the aspheric IOL group, and was 0.11+/-0.034/0.48+/-0.13 microm in the spherical IOL group. The internal Z(3)(-1) and total Z(3)(-1) were more negative in the spherical IOL group. The internal Z(3)(-3) was more negative in the aspheric IOL group. The two groups were similar in terms of other Zernike values and RMS of HOA. There were no differences in BCVA between groups. The aspheric IOL group showed better contrast sensitivity at 3-6 cpd in photopic and 1.5-6 cpd in mesopic conditions. The MTF curve was better for the aspheric IOL group at 5-10 cpd.

CONCLUSIONS: The aspheric IOL with a negative SA reduced total SA by compensating for positive corneal SA. These effects resulted in improved contrast sensitivity.
Full Text
http://www.nature.com/eye/journal/v22/n12/full/eye2008302a.html
DOI
10.1038/eye.2008.302
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eung Kweon(김응권) ORCID logo https://orcid.org/0000-0002-1453-8042
Kim, Tae-Im(김태임) ORCID logo https://orcid.org/0000-0001-6414-3842
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/108518
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links