1979 899

Cited 0 times in

구급차 이송 도중 자동제세동기의 정확도에 대한 연구

DC Field Value Language
dc.contributor.author김승호-
dc.contributor.author이한식-
dc.contributor.author정성필-
dc.contributor.author정현수-
dc.contributor.author조준호-
dc.date.accessioned2015-05-19T17:36:45Z-
dc.date.available2015-05-19T17:36:45Z-
dc.date.issued2008-
dc.identifier.issn1226-4334-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/108479-
dc.description.abstractPurpose: Current resuscitation guideline recommends not using the automated external defibrillator (AED) in a running ambulance, because artifact arising from movement of the ambulance can interfere with rhythm analysis of AED and can simulate ventricular fibrillation (VF). This study was conducted to determine whether the AED can be operated correctly in a running ambulance. Methods: Five AEDs were tested for their sensitivity, specificity, positive/negative predictive value, and accuracy. Each AED was connected to a manikin randomly simulating coarse and fine VF, asystole, and normal sinus rhythm, and each rhythm was analyzed 5 times by AEDs on the highway. Data about the shock recommendation given and delivery time interval from analysis to shock were collected. ECGs were also downloaded during the analysis time for a normal volunteer to search for baseline artifacts. Results: All AEDs recommended shock delivery correctly for the simulated rhythms whether the ambulance was stopped (0 km/h) or running on unpaved road (20 km/h). The sensitivity, specificity, positive/negative predictive value, and accuracy of AEDs on the highway (100 km/h) were similar to those obtained in previous studies on AED performance in pre-hospital settings. The recorded ECG rhythm of a volunteer in a running car showed no baseline artifacts. Conclusion: All AEDs recommended shock delivery correctly in a running ambulance. Therefore, the current recommendation of not using the AED on a running ambulance should be reconsidered-
dc.description.statementOfResponsibilityopen-
dc.format.extent449~453-
dc.relation.isPartOfJournal of the Korean Society of Emergency Medicine (대한응급의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title구급차 이송 도중 자동제세동기의 정확도에 대한 연구-
dc.title.alternativeAccuracy of Automated External Defibrillators During Ambulance Transport: Simulation Study-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Emergency Medicine (응급의학)-
dc.contributor.googleauthor조준호-
dc.contributor.googleauthor정성필-
dc.contributor.googleauthor정현수-
dc.contributor.googleauthor김승호-
dc.contributor.googleauthor이한식-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03278-
dc.contributor.localIdA03625-
dc.contributor.localIdA03911-
dc.contributor.localIdA00667-
dc.relation.journalcodeJ01868-
dc.identifier.pmidAutomated external defibrillator; Defibrillation; Transportation; Ambulances-
dc.subject.keywordAutomated external defibrillator-
dc.subject.keywordDefibrillation-
dc.subject.keywordTransportation-
dc.subject.keywordAmbulances-
dc.contributor.alternativeNameKim, Seung Ho-
dc.contributor.alternativeNameLee, Hahn Shick-
dc.contributor.alternativeNameChung, Sung Pil-
dc.contributor.alternativeNameChung, Hyun Soo-
dc.contributor.alternativeNameCho, Jun Ho-
dc.contributor.affiliatedAuthorLee, Hahn Shick-
dc.contributor.affiliatedAuthorChung, Sung Pil-
dc.contributor.affiliatedAuthorCho, Jun Ho-
dc.contributor.affiliatedAuthorKim, Seung Ho-
dc.rights.accessRightsfree-
dc.citation.volume19-
dc.citation.number5-
dc.citation.startPage449-
dc.citation.endPage453-
dc.identifier.bibliographicCitationJournal of the Korean Society of Emergency Medicine (대한응급의학회지), Vol.19(5) : 449-453, 2008-
dc.identifier.rimsid35607-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Emergency Medicine (응급의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.