332 521

Cited 0 times in

굴절교정수술 환자에서 Dynamic Contour Tonometer를 이용한 안압 측정

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.date.accessioned2015-05-19T17:06:24Z-
dc.date.available2015-05-19T17:06:24Z-
dc.date.issued2008-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/107516-
dc.description.abstractPurpose: To assess the performance of the dynamic contour tonometer (DCT) in eyes undergoing excimer laser photorefractive keratectomy (PRK). Methods: Intraocular pressure (IOP) was measured in 30 eyes after first time excimer laser PRK pre and three months post operatively using Goldmann applanation tonometer (GAT), noncontact air tonometer (NCT), and the DCT. Results: There was significant correlation between central corneal thickness (CCT) and IOP measurements by GAT and NCT (CCT vs GAT: r2=0.31, p<0.01, CCT vs NCT: r2=0.39, p<0.01). However, the correlation between CCT and IOP measurements by DCT was not significant (CCT vs DCT: r2=0.14, p=0.32). After PRK, the mean change in CCT and IOP measurements using GAT, NCT, DCT were 73.70±26.92 μm (mean±SD), 2.43±2.86 mmHg (p<0.01), 3.83±2.34 mmHg (p<0.01) and 0.44±1.51 mmHg (p=0.125), respectively. The preoperative and postoperative DCT measurements did not differ significantly. Conclusions: The reduction in CCT induced by PRK doesn`t appear to influence DCT measurements; therefore, DCT may be better suited over GAT or NCT for monitoring IOP in eyes that underwent refractive surgery-
dc.description.statementOfResponsibilityopen-
dc.format.extent577~582-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title굴절교정수술 환자에서 Dynamic Contour Tonometer를 이용한 안압 측정-
dc.title.alternativeIntraocular Pressure Measurements Using Dynamic Contour Tonometer After Photorefractive Keratectomy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor최현준-
dc.contributor.googleauthor김선웅-
dc.contributor.googleauthor김태임-
dc.contributor.googleauthor김응권-
dc.identifier.doi10.3341/jkos.2008.49.4.577-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.identifier.pmidCentral corneal thickness ; Pascal dynamic contour tonometer ; Photorefractive keratectomy-
dc.subject.keywordCentral corneal thickness-
dc.subject.keywordPascal dynamic contour tonometer-
dc.subject.keywordPhotorefractive keratectomy-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.rights.accessRightsfree-
dc.citation.volume49-
dc.citation.number4-
dc.citation.startPage577-
dc.citation.endPage582-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.49(4) : 577-582, 2008-
dc.identifier.rimsid57260-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.