385 741

Cited 0 times in

2종 전자근관장측정기의 일관성에 관한 in vitro 연구

DC Field Value Language
dc.contributor.author김의성-
dc.contributor.author노병덕-
dc.contributor.author이승종-
dc.date.accessioned2015-05-19T16:52:23Z-
dc.date.available2015-05-19T16:52:23Z-
dc.date.issued2008-
dc.identifier.issn1225-0864-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/107099-
dc.description.abstractThe purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder-
dc.description.statementOfResponsibilityopen-
dc.format.extent20~27-
dc.relation.isPartOfJournal of Korean Academy of Operative Dentistry (대한치과보존학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title2종 전자근관장측정기의 일관성에 관한 in vitro 연구-
dc.title.alternativeIn vitro evaluation of the consistency of two electronic apex locators-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학)-
dc.contributor.googleauthor황규용-
dc.contributor.googleauthor노병덕-
dc.contributor.googleauthor김의성-
dc.contributor.googleauthor이승종-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00833-
dc.contributor.localIdA01280-
dc.contributor.localIdA02925-
dc.relation.journalcodeJ01488-
dc.identifier.pmidElectronic apex locator , accuracy , consistency , Micro­CT-
dc.subject.keywordElectronic apex locator , accuracy , consistency , Micro­CT-
dc.contributor.alternativeNameKim, Eui Seong-
dc.contributor.alternativeNameRoh, Byoung Duck-
dc.contributor.alternativeNameLee, Seung Jong-
dc.contributor.affiliatedAuthorKim, Eui Seong-
dc.contributor.affiliatedAuthorRoh, Byoung Duck-
dc.contributor.affiliatedAuthorLee, Seung Jong-
dc.rights.accessRightsfree-
dc.citation.volume33-
dc.citation.number1-
dc.citation.startPage20-
dc.citation.endPage27-
dc.identifier.bibliographicCitationJournal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.33(1) : 20-27, 2008-
dc.identifier.rimsid49532-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.