Whole-body biodistribution and radiation dosimetry in monkeys and humans of the phosphodiesterase 4 radioligand [(11)C](R)-rolipram: comparison of two-dimensional planar, bisected and quadrisected image analyses

Authors
 David R. Sprague  ;  Masahiro Fujita  ;  Yong Hoon Ryu  ;  Jeih-San Liow  ;  Victor W. Pike  ;  Robert B. Innis 
Citation
 NUCLEAR MEDICINE AND BIOLOGY, Vol.35(4) : 493-500, 2008 
Journal Title
NUCLEAR MEDICINE AND BIOLOGY
ISSN
 0969-8051 
Issue Date
2008
MeSH
Animals ; Carbon Radioisotopes/metabolism* ; Cyclic Nucleotide Phosphodiesterases, Type 4/analysis ; Haplorhini ; Humans ; Metabolic Clearance Rate ; Phosphodiesterase 4 Inhibitors ; Positron-Emission Tomography/methods* ; Radiation Dosage* ; Radiopharmaceuticals/metabolism ; Rolipram/metabolism* ; Tissue Distribution ; Whole Body Imaging ; Whole-Body Counting
Keywords
[11C](R)-Rolipram ; Positron emission tomography ; Dosimetry ; Biodistribution
Abstract
INTRODUCTION: [(11)C](R)-Rolipram is a selective radioligand for positron emission tomography (PET) imaging of phosphodiesterase 4, an enzyme that metabolizes 3',5'-cyclic adenosine monophosphate. The aim of this study was to estimate the human radiation absorbed dose of the radioligand based on its biodistribution in both monkeys and humans.

METHODS: Whole-body PET images were acquired for 2 h after injecting [(11)C](R)-rolipram in eight healthy humans and three monkeys. The simple method of using a single two-dimensional (2D) planar image was compared to more time-consuming methods that used two (bisected) or four (quadrisected) tomographic images in the anteroposterior direction.

RESULTS: Effective dose was 4.8 microGy/MBq based on 2D planar images. The effective dose was only slightly lower by 1% and 5% using the bisected and quadrisected images, respectively. Nevertheless, the two tomographic methods may have more accurately estimated the exposure of some organs (e.g., kidneys) that are asymmetrically located in the body or have radioactivity that appears to overlap on 2D planar images. Monkeys had a different biodistribution pattern compared to humans (e.g., greater urinary excretion) such that their data overestimated the effective dose in humans by 40%.

CONCLUSIONS: The effective dose of [(11)C](R)-rolipram was modest and comparable to that of other (11)C-labeled radioligands. The simple and far less time-consuming 2D planar method provided accurate and somewhat more conservative estimates of effective dose than the two tomographic methods. Although monkeys are commonly used to estimate human radiation exposures, their data gave a considerable overestimation for this radioligand
Files in This Item:
T200800773.pdf Download
DOI
10.1016/j.nucmedbio.2008.02.004
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers
Yonsei Authors
Ryu, Young Hoon(유영훈) ORCID logo https://orcid.org/0000-0002-9000-5563
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/107039
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links