Cited 0 times in
Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이형근 | - |
dc.contributor.author | 김성수 | - |
dc.contributor.author | 김찬윤 | - |
dc.contributor.author | 마경탁 | - |
dc.contributor.author | 성공제 | - |
dc.date.accessioned | 2015-05-19T16:20:31Z | - |
dc.date.available | 2015-05-19T16:20:31Z | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 1542-8877 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/106130 | - |
dc.description.abstract | A 39-year-old man with Marfan syndrome underwent scleral fixation using a three-piece foldable intraocular lens and experienced repeated pupillary intraocular lens captures secondary to a pliable iris. As a result, the patient needed an additional pupilloplasty. In the opposite eye, a silicone plate haptic intraocular lens was used for scleral fixation because it was thought that the plate design could prevent pupillary intraocular lens capture, even in cases involving a pliable iris. At the 27-month follow-up examination, the patient showed good centration of the intraocular lens in the eye that used the silicone plate haptic intraocular lens without pupillary intraocular lens capture | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 335~338 | - |
dc.relation.isPartOf | OPHTHALMIC SURGERY LASERS & IMAGING | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Lens Implantation, Intraocular/methods* | - |
dc.subject.MESH | Lenses, Intraocular* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Marfan Syndrome/complications | - |
dc.subject.MESH | Pupil Disorders/etiology* | - |
dc.subject.MESH | Recurrence | - |
dc.subject.MESH | Sclera/surgery* | - |
dc.subject.MESH | Silicone Elastomers* | - |
dc.subject.MESH | Suture Techniques | - |
dc.subject.MESH | Visual Acuity | - |
dc.title | Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Kyoung Tak Ma | - |
dc.contributor.googleauthor | Sung Soo Kim | - |
dc.contributor.googleauthor | Gong Jae Seong | - |
dc.contributor.googleauthor | Hyung Keun Lee | - |
dc.contributor.googleauthor | Chan Yun Kim | - |
dc.identifier.doi | 10.3928/15428877-20080701-11 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00571 | - |
dc.contributor.localId | A03303 | - |
dc.contributor.localId | A01035 | - |
dc.contributor.localId | A01341 | - |
dc.contributor.localId | A01946 | - |
dc.relation.journalcode | J02429 | - |
dc.identifier.eissn | 1938-2375 | - |
dc.identifier.pmid | 18717443 | - |
dc.identifier.url | http://www.healio.com/ophthalmology/journals/osli/2008-7-39-4/%7B849c4427-68a7-4951-ab05-14413ff0e919%7D/scleral-fixation-of-a-silicone-plate-haptic-intraocular-lens-in-a-patient-showing-repeated-pupillary-intraocular-lens-capture | - |
dc.subject.keyword | Adult | - |
dc.subject.keyword | Humans | - |
dc.subject.keyword | Lens Implantation, Intraocular/methods* | - |
dc.subject.keyword | Lenses, Intraocular* | - |
dc.subject.keyword | Male | - |
dc.subject.keyword | Marfan Syndrome/complications | - |
dc.subject.keyword | Pupil Disorders/etiology* | - |
dc.subject.keyword | Recurrence | - |
dc.subject.keyword | Sclera/surgery* | - |
dc.subject.keyword | Silicone Elastomers* | - |
dc.subject.keyword | Suture Techniques | - |
dc.subject.keyword | Visual Acuity | - |
dc.contributor.alternativeName | Lee, Hyung Keun | - |
dc.contributor.alternativeName | Kim, Sung Soo | - |
dc.contributor.alternativeName | Kim, Chan Yun | - |
dc.contributor.alternativeName | Ma, Kyung Tak | - |
dc.contributor.alternativeName | Seong, Gong Je | - |
dc.contributor.affiliatedAuthor | Kim, Sung Soo | - |
dc.contributor.affiliatedAuthor | Lee, Hyung Keun | - |
dc.contributor.affiliatedAuthor | Kim, Chan Yun | - |
dc.contributor.affiliatedAuthor | Ma, Kyung Tak | - |
dc.contributor.affiliatedAuthor | Seong, Gong Je | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 39 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 335 | - |
dc.citation.endPage | 338 | - |
dc.identifier.bibliographicCitation | OPHTHALMIC SURGERY LASERS & IMAGING , Vol.39(4) : 335-338, 2008 | - |
dc.identifier.rimsid | 54739 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.