0 495

Cited 0 times in

Comparison of fracture resistance of pressable metal ceramic custom implant abutments with CAD/CAM commercially fabricated zirconia implant abutments

Authors
 Sungtae Kim  ;  Hyeong-Il Kim  ;  Jane D.Brewer  ;  Edward A. Monaco 
Citation
 JOURNAL OF PROSTHETIC DENTISTRY, Vol.101(4) : 226-230, 2009 
Journal Title
JOURNAL OF PROSTHETIC DENTISTRY
ISSN
 0022-3913 
Issue Date
2009
MeSH
Dental Abutments* ; Dental Implants* ; Dental Prosthesis Design* ; Dental Restoration Failure ; Dental Stress Analysis* ; Humans ; Materials Testing ; Metal Ceramic Alloys* ; Zirconium
Abstract
STATEMENT OF PROBLEM: The adequacy of the strength of dental zirconia abutments under heavy occlusal load conditions is questionable, with degradation of the mechanical properties of zirconia having been reported. Therefore, some alternatives must be considered.

PURPOSE: The purpose of this study was to determine the efficacy of fabricating pressable metal ceramic custom implant (Pr) abutments, and to evaluate the fracture resistance of these abutments.

MATERIAL AND METHODS: Two groups of implant abutment specimens were fabricated (n=10). The experimental group consisted of Pr abutments, and the control group consisted of CAD/CAM-designed zirconia-based ceramic (Zr) abutments. For the experimental group, custom metal abutments were cast using a compatible metal alloy (Lodestar); this was followed by injection molding with lithium disilicate pressable ceramic (IPS e.max Press) around the metal column of the custom implant abutment. For the control group, 10 specimens were fabricated from CAD/CAM-designed zirconia abutments (Procera Zirconia). Following scanning, all-ceramic crowns with the average dimensions of a human central incisor were fabricated for the experimental and control abutments (n=20) using lithium disilicate pressable ceramic (IPS e.max Press). Each crown was cemented to the implant abutments with a resin luting agent (Variolink II). The crown-abutment test specimens were fixed to titanium implant analogs and placed in a test stand at 30 degrees from the vertical axis of the specimens in a computer-controlled universal testing device. The independent t test was used to detect if the mean values of the fracture load differed significantly (alpha=.05) between the 2 groups.

RESULTS: The mean (SD) fracture load was significantly higher in the Pr group (901.67 (102.05) N) than in the Zr group (480.01 (174.46) N, P<.005).

CONCLUSIONS: This study found that Pr abutments are stronger than Zr abutments.
Full Text
http://www.sciencedirect.com/science/article/pii/S0022391309600433
DOI
10.1016/S0022-3913(09)60043-3
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sung Tae(김성태)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/105829
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links