3 628

Cited 0 times in

Comparative analysis of peri-implant marginal bone loss based on microthread location: a 1-year prospective study after loading.

DC Field Value Language
dc.contributor.author김종관-
dc.contributor.author문익상-
dc.contributor.author박광호-
dc.contributor.author이동원-
dc.date.accessioned2015-04-24T17:34:18Z-
dc.date.available2015-04-24T17:34:18Z-
dc.date.issued2009-
dc.identifier.issn0022-3492-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/105653-
dc.description.abstractBACKGROUND: The purpose of the present study was to investigate the short-term effects of microthread location on peri-implant marginal bone levels. METHODS: Two types of implants, one with microthreads placed at the implant top (group A) and the other with microthreads placed 0.5 mm below the implant top (group B), were placed adjacent to each other in the partially edentulous areas of 20 patients. In total, 40 implants were placed. Bone loss around each implant was analyzed after 1 year of functional loading, and gingival parameters (modified plaque index and modified sulcus bleeding index) of the peri-implant soft tissue were evaluated. Bone losses after loading and gingival parameters were compared using the paired t test. RESULTS: The average bone loss was 0.16 (SD: 0.19) mm in group A and 0.30 (SD: 0.22) mm in group B after 1-year of functional loading. The paired t test revealed a significant difference in crestal bone loss between groups A and B in individual patients (P = 0.004). No significant differences were found between the two groups for the gingival parameters. CONCLUSIONS: Less peri-implant bone loss was observed around implants with microthreads placed at the implant top (group A) compared to those in which microthreads were placed below the top (group B). These results indicated that the microthreads acted to stabilize the peri-implant marginal bone, and their locations played an important role in the stabilization process.-
dc.description.statementOfResponsibilityopen-
dc.format.extent1937~1944-
dc.relation.isPartOfJOURNAL OF PERIODONTOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAlveolar Bone Loss/classification*-
dc.subject.MESHDental Implantation, Endosseous/methods-
dc.subject.MESHDental Implants*-
dc.subject.MESHDental Materials/chemistry-
dc.subject.MESHDental Plaque Index-
dc.subject.MESHDental Prosthesis Design*-
dc.subject.MESHDental Prosthesis, Implant-Supported-
dc.subject.MESHDenture, Partial-
dc.subject.MESHFemale-
dc.subject.MESHFollow-Up Studies-
dc.subject.MESHGingival Hemorrhage/classification-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHJaw, Edentulous, Partially/rehabilitation-
dc.subject.MESHJaw, Edentulous, Partially/surgery-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPeriodontal Index-
dc.subject.MESHProspective Studies-
dc.subject.MESHRadiography, Bitewing-
dc.subject.MESHSurface Properties-
dc.subject.MESHTitanium/chemistry-
dc.titleComparative analysis of peri-implant marginal bone loss based on microthread location: a 1-year prospective study after loading.-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Periodontology (치주과학)-
dc.contributor.googleauthorDong-Wook Song-
dc.contributor.googleauthorDong-Won Lee-
dc.contributor.googleauthorChong-Kwan Kim-
dc.contributor.googleauthorKwang-Ho Park-
dc.contributor.googleauthorIk-Sang Moon-
dc.identifier.doi10.1902/jop.2009.090330-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01373-
dc.contributor.localIdA01435-
dc.contributor.localIdA02728-
dc.contributor.localIdA00914-
dc.relation.journalcodeJ01697-
dc.identifier.eissn1943-3670-
dc.identifier.pmid19961377-
dc.identifier.urlhttp://www.joponline.org/doi/abs/10.1902/jop.2009.090330-
dc.subject.keywordAlveolar bone loss-
dc.subject.keyworddental implants-
dc.subject.keyworddental radiography-
dc.subject.keywordprospective studies-
dc.contributor.alternativeNameKim, Chong Kwan-
dc.contributor.alternativeNameMoon, Ik Sang-
dc.contributor.alternativeNamePark, Kwang Ho-
dc.contributor.alternativeNameLee, Dong Won-
dc.contributor.affiliatedAuthorMoon, Ik Sang-
dc.contributor.affiliatedAuthorPark, Kwang Ho-
dc.contributor.affiliatedAuthorLee, Dong Won-
dc.contributor.affiliatedAuthorKim, Chong Kwan-
dc.citation.volume80-
dc.citation.number12-
dc.citation.startPage1937-
dc.citation.endPage1944-
dc.identifier.bibliographicCitationJOURNAL OF PERIODONTOLOGY, Vol.80(12) : 1937-1944, 2009-
dc.identifier.rimsid40943-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Oral and Maxillofacial Surgery (구강악안면외과학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.