345 517

Cited 0 times in

세 종류의 비구면 인공수정체 간의 술 후 구면수차, 대비감도 및 초점심도 정도의 비교

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.date.accessioned2015-04-24T17:26:46Z-
dc.date.available2015-04-24T17:26:46Z-
dc.date.issued2009-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/105414-
dc.description.abstractPurpose: To evaluate postoperative spherical aberration, contrast sensitivity and depth of focus after implanting 3 different aspheric intraocular lenses. Methods: Fifty-six eyes (18 eyes for Akreos adapt Advanced Optics (AO), 20 eyes for AcrySof IQ SN60WF and 18 eyes for Tecnis Acrylic IOL ZA9003) of 48 patients were evaluated. Internal ocular aberration including spherical aberration and higher-order aberration and contrast sensitivity were evaluated 3 months after lens implantation. In addition, visual acuities at 33 cm and 1 m distance were measured with the far vision corrected state to calculate depth of focus. Results: The total and internal ocular spherical aberration of the AO implanted group was slightly higher than the other groups with statistical significance. However, there was no statistically significant difference of contrast sensitivity and depth of focus among the 3 groups. Conclusions: A subtle difference of spherical aberration among the 3 groups without a statistically significant difference in other factors may not induce the differences of contrast sensitivities and depths of focus in each group-
dc.description.statementOfResponsibilityopen-
dc.format.extent1639~1644-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title세 종류의 비구면 인공수정체 간의 술 후 구면수차, 대비감도 및 초점심도 정도의 비교-
dc.title.alternativeSpherical Aberration, Contrast Sensitivity and Depth of Focus With Three Aspherical Intraocular Lenses-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor배형원-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2009.50.11.1639-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordAspheric intraocular lens-
dc.subject.keywordContrast sensitivity-
dc.subject.keywordDepth of focus-
dc.subject.keywordSpherical aberration-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.citation.volume50-
dc.citation.number11-
dc.citation.startPage1639-
dc.citation.endPage1644-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.50(11) : 1639-1644, 2009-
dc.identifier.rimsid51671-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.