Cited 24 times in
The usefulness of the GlideScope video laryngoscope in the education of conventional tracheal intubation for the novice.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박유석 | - |
dc.contributor.author | 정성필 | - |
dc.date.accessioned | 2015-04-24T17:22:20Z | - |
dc.date.available | 2015-04-24T17:22:20Z | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 1472-0205 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/105274 | - |
dc.description.abstract | The aim of this study is to evaluate the usefulness of the GlideScope video laryngoscope (GVL) as a tool to educate novice users in conventional tracheal intubation. 41 premedical students with no previous experience in tracheal intubation participated in this prospective, randomised and controlled study. Group M (n = 20) was instructed in tracheal intubation by using the Macintosh laryngoscope and group G (n = 21) was instructed by using both the GVL and the Macintosh laryngoscope. There was no significant difference in tracheal intubation performance using the Macintosh laryngoscope between the two groups. However, the GVL facilitates the education of tracheal intubation because it shows the same anatomical structure for both instructor and trainee simultaneously on a real-time basis. This aspect makes the trainee feel more comfortable learning the material with a high degree of satisfaction. Introducing GVL to conventional intubation education for novice users could increase the satisfaction of trainees during the procedure, especially as a way to understand critical anatomical structures. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 109~111 | - |
dc.relation.isPartOf | EMERGENCY MEDICINE JOURNAL | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Clinical Competence/standards* | - |
dc.subject.MESH | Education, Premedical/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intubation, Intratracheal/instrumentation | - |
dc.subject.MESH | Intubation, Intratracheal/standards* | - |
dc.subject.MESH | Korea | - |
dc.subject.MESH | Laryngoscopes* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Personal Satisfaction | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Teaching Materials | - |
dc.subject.MESH | Video Recording* | - |
dc.title | The usefulness of the GlideScope video laryngoscope in the education of conventional tracheal intubation for the novice. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Emergency Medicine (응급의학) | - |
dc.contributor.googleauthor | J S You | - |
dc.contributor.googleauthor | S Park | - |
dc.contributor.googleauthor | S P Chung | - |
dc.contributor.googleauthor | Y S Park | - |
dc.contributor.googleauthor | J W Park | - |
dc.identifier.doi | 10.1136/emj.2008.059147 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A01592 | - |
dc.contributor.localId | A03625 | - |
dc.relation.journalcode | J00766 | - |
dc.identifier.eissn | 1472-0213 | - |
dc.identifier.pmid | 19164620 | - |
dc.identifier.url | http://emj.bmj.com/content/26/2/109.long | - |
dc.contributor.alternativeName | Park, Yoo Seok | - |
dc.contributor.alternativeName | Chung, Sung Pil | - |
dc.contributor.affiliatedAuthor | Park, Yoo Seok | - |
dc.contributor.affiliatedAuthor | Chung, Sung Pil | - |
dc.citation.volume | 26 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 109 | - |
dc.citation.endPage | 111 | - |
dc.identifier.bibliographicCitation | EMERGENCY MEDICINE JOURNAL, Vol.26(2) : 109-111, 2009 | - |
dc.identifier.rimsid | 54266 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.