Cited 0 times in
Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김창성 | - |
dc.contributor.author | 조규성 | - |
dc.contributor.author | 최성호 | - |
dc.date.accessioned | 2015-04-24T17:03:37Z | - |
dc.date.available | 2015-04-24T17:03:37Z | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 2093-2278 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/104683 | - |
dc.description.abstract | PURPOSE: The purpose of the present study was to analyze the implant stability quotient(ISQ) values for Korean non-submerged type implant and determine the factors that affect implant stability. METHODS: A total of 49 Korean non-submerged type implants were installed in 24 patients, and their stability was measured by resonance frequency analysis(RFA) at the time of surgery, and 1, 2, 3, 4, 8, 12 weeks postoperatively. The data for implant site, age, sex, implant length and diameter, graft performing, bone type, and insertion torque were analyzed. RESULTS: The lowest mean stability measurement was at 3 weeks. There was significant difference between implant placement and 12 weeks. There was significant difference between implant placement and 12 weeks in diameters of 4.1 mm and 4.8 mm. Also, there were significant differences between diameters of 4.1 mm and 4.8 mm at implant placement and 12 weeks after surgery. This result suggests that the factor related to implant diameter may affect the level of implant stability. No statistically significant relationship was found between the resonance frequency analysis and the variables of maxilla/mandible, sex, anterior/posterior, implant length, age of patient, graft performing, bone type, insertion torque during initial healing period. CONCLUSIONS: These findings suggest that the factor related to implant diameter may affect the variance of implant stability, and ISQ value of implant was stable enough for proved stability level during initial healing period | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 339~348 | - |
dc.relation.isPartOf | Journal of Korean Academy of Periodontology (대한치주과학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석 | - |
dc.title.alternative | Non-submerged type implant stability analysis during initial healing period by resonance frequency analysis. | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Periodontology (치주과학) | - |
dc.contributor.googleauthor | 김득한 | - |
dc.contributor.googleauthor | 방은경 | - |
dc.contributor.googleauthor | 김창성 | - |
dc.contributor.googleauthor | 최성호 | - |
dc.contributor.googleauthor | 조규성 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A01041 | - |
dc.contributor.localId | A03810 | - |
dc.contributor.localId | A04081 | - |
dc.relation.journalcode | J01492 | - |
dc.subject.keyword | maxillary sinus | - |
dc.subject.keyword | dental implants | - |
dc.subject.keyword | survival rate | - |
dc.contributor.alternativeName | Kim, Chang Sung | - |
dc.contributor.alternativeName | Cho, Kyoo Sung | - |
dc.contributor.alternativeName | Choi, Seong Ho | - |
dc.contributor.affiliatedAuthor | Kim, Chang Sung | - |
dc.contributor.affiliatedAuthor | Cho, Kyoo Sung | - |
dc.contributor.affiliatedAuthor | Choi, Seong Ho | - |
dc.citation.volume | 39 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 339 | - |
dc.citation.endPage | 348 | - |
dc.identifier.bibliographicCitation | Journal of Korean Academy of Periodontology (대한치주과학회지), Vol.39(3) : 339-348, 2009 | - |
dc.identifier.rimsid | 52858 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.