354 577

Cited 16 times in

Detection of occludable angles with the Pentacam and the anterior segment optical coherence tomography

DC Field Value Language
dc.contributor.author강성용-
dc.contributor.author김찬윤-
dc.contributor.author성공제-
dc.contributor.author홍사민-
dc.date.accessioned2015-04-24T16:49:18Z-
dc.date.available2015-04-24T16:49:18Z-
dc.date.issued2009-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/104236-
dc.description.abstractPURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles.-
dc.description.statementOfResponsibilityopen-
dc.format.extent525~528-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHAnterior Chamber/anatomy & histology*-
dc.subject.MESHHumans-
dc.subject.MESHMiddle Aged-
dc.subject.MESHTomography, Optical Coherence/methods*-
dc.titleDetection of occludable angles with the Pentacam and the anterior segment optical coherence tomography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorSamin Hong-
dc.contributor.googleauthorJeong-Ho Yi-
dc.contributor.googleauthorSung Yong Kang-
dc.contributor.googleauthorGong Je Seong-
dc.contributor.googleauthorChan Yun Kim-
dc.identifier.doi10.3349/ymj.2009.50.4.525-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00040-
dc.contributor.localIdA01035-
dc.contributor.localIdA01946-
dc.contributor.localIdA04395-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid19718401-
dc.subject.keywordPentacam-
dc.subject.keywordanterior chamber angle-
dc.subject.keywordanterior chamber depth-
dc.subject.keywordanterior segment optical coherence tomography-
dc.subject.keywordoccludable angle-
dc.contributor.alternativeNameKang, Sung Yong-
dc.contributor.alternativeNameKim, Chan Yun-
dc.contributor.alternativeNameSeong, Gong Je-
dc.contributor.alternativeNameHong, Sa Min-
dc.contributor.affiliatedAuthorKang, Sung Yong-
dc.contributor.affiliatedAuthorKim, Chan Yun-
dc.contributor.affiliatedAuthorSeong, Gong Je-
dc.contributor.affiliatedAuthorHong, Sa Min-
dc.citation.volume50-
dc.citation.number4-
dc.citation.startPage525-
dc.citation.endPage528-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.50(4) : 525-528, 2009-
dc.identifier.rimsid56132-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.