dc.description.abstract | PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 525~528 | - |
dc.relation.isPartOf | YONSEI MEDICAL JOURNAL | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Anterior Chamber/anatomy & histology* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Tomography, Optical Coherence/methods* | - |
dc.title | Detection of occludable angles with the Pentacam and the anterior segment optical coherence tomography | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Samin Hong | - |
dc.contributor.googleauthor | Jeong-Ho Yi | - |
dc.contributor.googleauthor | Sung Yong Kang | - |
dc.contributor.googleauthor | Gong Je Seong | - |
dc.contributor.googleauthor | Chan Yun Kim | - |
dc.identifier.doi | 10.3349/ymj.2009.50.4.525 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00040 | - |
dc.contributor.localId | A01035 | - |
dc.contributor.localId | A01946 | - |
dc.contributor.localId | A04395 | - |
dc.relation.journalcode | J02813 | - |
dc.identifier.eissn | 1976-2437 | - |
dc.identifier.pmid | 19718401 | - |
dc.subject.keyword | Pentacam | - |
dc.subject.keyword | anterior chamber angle | - |
dc.subject.keyword | anterior chamber depth | - |
dc.subject.keyword | anterior segment optical coherence tomography | - |
dc.subject.keyword | occludable angle | - |
dc.contributor.alternativeName | Kang, Sung Yong | - |
dc.contributor.alternativeName | Kim, Chan Yun | - |
dc.contributor.alternativeName | Seong, Gong Je | - |
dc.contributor.alternativeName | Hong, Sa Min | - |
dc.contributor.affiliatedAuthor | Kang, Sung Yong | - |
dc.contributor.affiliatedAuthor | Kim, Chan Yun | - |
dc.contributor.affiliatedAuthor | Seong, Gong Je | - |
dc.contributor.affiliatedAuthor | Hong, Sa Min | - |
dc.citation.volume | 50 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 525 | - |
dc.citation.endPage | 528 | - |
dc.identifier.bibliographicCitation | YONSEI MEDICAL JOURNAL, Vol.50(4) : 525-528, 2009 | - |
dc.identifier.rimsid | 56132 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.