Cited 0 times in
Use of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김상우 | - |
dc.contributor.author | 김응권 | - |
dc.contributor.author | 김태임 | - |
dc.date.accessioned | 2015-04-24T16:34:13Z | - |
dc.date.available | 2015-04-24T16:34:13Z | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 1081-597X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/103761 | - |
dc.description.abstract | PURPOSE: To assess the accuracy and validity of true net corneal power of the Pentacam system to provide a keratometry reading for calculating intraocular lens (IOL) power in postoperative refractive surgery eyes. METHODS: Refraction, an automated keratometry reading, and true net corneal power were measured for 30 eyes that required cataract surgery and had previously undergone refractive surgery. Target refraction values calculated with the SRK/T formula using true net corneal power were compared with postoperative manifest refraction values. RESULTS: Using true net corneal power, the mean deviation from the desired postoperative cataract refractive outcome was 0.47 +/- 0.56 diopters (D); the actual refraction was within +/- 0.50 D of the intended refraction for 70% of eyes (21/30) and within +/- 1.00 D for 93% of eyes (28/30). CONCLUSIONS: The true net corneal power can be used as a keratometry reading for eyes with previous refractive surgery requiring cataract surgery. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 285~289 | - |
dc.relation.isPartOf | JOURNAL OF REFRACTIVE SURGERY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Algorithms* | - |
dc.subject.MESH | Cataract Extraction | - |
dc.subject.MESH | Cornea/physiopathology* | - |
dc.subject.MESH | Cornea/surgery* | - |
dc.subject.MESH | Corneal Topography | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Lens Implantation, Intraocular | - |
dc.subject.MESH | Lenses, Intraocular* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Myopia/physiopathology | - |
dc.subject.MESH | Myopia/surgery | - |
dc.subject.MESH | Refraction, Ocular/physiology* | - |
dc.subject.MESH | Refractive Surgical Procedures* | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.title | Use of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Sang Woo Kim | - |
dc.contributor.googleauthor | Eung Kweon Kim | - |
dc.contributor.googleauthor | Beom-Jin Cho | - |
dc.contributor.googleauthor | Sun Woong Kim | - |
dc.contributor.googleauthor | Ki Yung Song | - |
dc.contributor.googleauthor | Tae-im Kim | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.contributor.localId | A00525 | - |
dc.relation.journalcode | J01730 | - |
dc.identifier.pmid | 19370824 | - |
dc.identifier.url | http://www.healio.com/ophthalmology/refractive-surgery/journals/jrs/%7B6940a73a-455b-4aac-9068-c0a88d6dfdc3%7D/use-of-the-pentacam-true-net-cornealpower-for-intraocular-lens-calculation-in-eyes-after-refractive-corneal-surgery | - |
dc.contributor.alternativeName | Kim, Sang Woo | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Kim, Sang Woo | - |
dc.citation.volume | 25 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 285 | - |
dc.citation.endPage | 289 | - |
dc.identifier.bibliographicCitation | JOURNAL OF REFRACTIVE SURGERY, Vol.25(3) : 285-289, 2009 | - |
dc.identifier.rimsid | 36674 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.