0 591

Cited 0 times in

Use of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery.

DC Field Value Language
dc.contributor.author김상우-
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.date.accessioned2015-04-24T16:34:13Z-
dc.date.available2015-04-24T16:34:13Z-
dc.date.issued2009-
dc.identifier.issn1081-597X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/103761-
dc.description.abstractPURPOSE: To assess the accuracy and validity of true net corneal power of the Pentacam system to provide a keratometry reading for calculating intraocular lens (IOL) power in postoperative refractive surgery eyes. METHODS: Refraction, an automated keratometry reading, and true net corneal power were measured for 30 eyes that required cataract surgery and had previously undergone refractive surgery. Target refraction values calculated with the SRK/T formula using true net corneal power were compared with postoperative manifest refraction values. RESULTS: Using true net corneal power, the mean deviation from the desired postoperative cataract refractive outcome was 0.47 +/- 0.56 diopters (D); the actual refraction was within +/- 0.50 D of the intended refraction for 70% of eyes (21/30) and within +/- 1.00 D for 93% of eyes (28/30). CONCLUSIONS: The true net corneal power can be used as a keratometry reading for eyes with previous refractive surgery requiring cataract surgery.-
dc.description.statementOfResponsibilityopen-
dc.format.extent285~289-
dc.relation.isPartOfJOURNAL OF REFRACTIVE SURGERY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAlgorithms*-
dc.subject.MESHCataract Extraction-
dc.subject.MESHCornea/physiopathology*-
dc.subject.MESHCornea/surgery*-
dc.subject.MESHCorneal Topography-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLens Implantation, Intraocular-
dc.subject.MESHLenses, Intraocular*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHMyopia/physiopathology-
dc.subject.MESHMyopia/surgery-
dc.subject.MESHRefraction, Ocular/physiology*-
dc.subject.MESHRefractive Surgical Procedures*-
dc.subject.MESHReproducibility of Results-
dc.titleUse of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorSang Woo Kim-
dc.contributor.googleauthorEung Kweon Kim-
dc.contributor.googleauthorBeom-Jin Cho-
dc.contributor.googleauthorSun Woong Kim-
dc.contributor.googleauthorKi Yung Song-
dc.contributor.googleauthorTae-im Kim-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA00525-
dc.relation.journalcodeJ01730-
dc.identifier.pmid19370824-
dc.identifier.urlhttp://www.healio.com/ophthalmology/refractive-surgery/journals/jrs/%7B6940a73a-455b-4aac-9068-c0a88d6dfdc3%7D/use-of-the-pentacam-true-net-cornealpower-for-intraocular-lens-calculation-in-eyes-after-refractive-corneal-surgery-
dc.contributor.alternativeNameKim, Sang Woo-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorKim, Sang Woo-
dc.citation.volume25-
dc.citation.number3-
dc.citation.startPage285-
dc.citation.endPage289-
dc.identifier.bibliographicCitationJOURNAL OF REFRACTIVE SURGERY, Vol.25(3) : 285-289, 2009-
dc.identifier.rimsid36674-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.