Cited 0 times in
하행 대동맥 내 스텐트-도관 삽입 후 발생한 역행성 대동맥 박리
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 윤영남 | - |
dc.contributor.author | 이희정 | - |
dc.contributor.author | 홍순창 | - |
dc.date.accessioned | 2015-04-23T17:43:44Z | - |
dc.date.available | 2015-04-23T17:43:44Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 3012-2859 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/103016 | - |
dc.description.abstract | In current era, thoracic endovascular aortic repair (TEVAR) has gained popularity. But, it bears the risk of serious complications such as treatment failure from endoleak, retrograde aortic dissection caused by injury of aortic wall at landing zone, or aortic rupture resulting from stent graft infection. We report two cases of surgical repair of retrograde aortic dissection after TAVAR applied to acute Stanford type B aortic dissection or traumatic aortic disruption | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 758~763 | - |
dc.relation.isPartOf | Korean Journal of Thoracic and Cardiovascular Surgery (대한흉부외과학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 하행 대동맥 내 스텐트-도관 삽입 후 발생한 역행성 대동맥 박리 | - |
dc.title.alternative | Retrograde Aortic Dissection after Thoracic Endovascular Aortic Repair for Descending Aorta - 2 case reports - | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Medical Research Center (임상의학연구센터) | - |
dc.contributor.googleauthor | 홍순창 | - |
dc.contributor.googleauthor | 김정환 | - |
dc.contributor.googleauthor | 이희정 | - |
dc.contributor.googleauthor | 윤영남 | - |
dc.identifier.doi | 10.5090/kjtcs.2010.43.6.758 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A02576 | - |
dc.contributor.localId | A03350 | - |
dc.contributor.localId | A04412 | - |
dc.relation.journalcode | J02127 | - |
dc.subject.keyword | Aortic dissection | - |
dc.subject.keyword | Endovascular stent | - |
dc.subject.keyword | Aneurysm, dissection | - |
dc.contributor.alternativeName | Youn, Young Nam | - |
dc.contributor.alternativeName | Lee, Hee Jeong | - |
dc.contributor.alternativeName | Hong, Soon Chang | - |
dc.contributor.affiliatedAuthor | Youn, Young Nam | - |
dc.contributor.affiliatedAuthor | Lee, Hee Jeong | - |
dc.contributor.affiliatedAuthor | Hong, Soon Chang | - |
dc.citation.volume | 43 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 758 | - |
dc.citation.endPage | 763 | - |
dc.identifier.bibliographicCitation | Korean Journal of Thoracic and Cardiovascular Surgery (대한흉부외과학회지), Vol.43(6) : 758-763, 2010 | - |
dc.identifier.rimsid | 35624 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.