624 874

Cited 0 times in

2 종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구

DC Field Value Language
dc.contributor.author김의성-
dc.contributor.author이승종-
dc.contributor.author정일영-
dc.date.accessioned2015-04-23T17:38:26Z-
dc.date.available2015-04-23T17:38:26Z-
dc.date.issued2010-
dc.identifier.issn1225-0864-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/102849-
dc.description.abstractObjectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.-
dc.description.statementOfResponsibilityopen-
dc.format.extent453~460-
dc.relation.isPartOfJournal of Korean Academy of Operative Dentistry (대한치과보존학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title2 종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구-
dc.title.alternativeIn vivo evaluation of accuracy and consistency of two electronic apex locators-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학)-
dc.contributor.googleauthor필감운-
dc.contributor.googleauthor김의성-
dc.contributor.googleauthor정일영-
dc.contributor.googleauthor이승종-
dc.identifier.doi10.5395/JKACD.2010.35.6.453-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00833-
dc.contributor.localIdA02925-
dc.contributor.localIdA03700-
dc.relation.journalcodeJ01488-
dc.subject.keywordAccuracy-
dc.subject.keywordConsistency-
dc.subject.keywordElectronic apex locator-
dc.subject.keywordMicroscope-
dc.contributor.alternativeNameKim, Eui Seong-
dc.contributor.alternativeNameLee, Seung Jong-
dc.contributor.alternativeNameJung, Il Young-
dc.contributor.affiliatedAuthorKim, Eui Seong-
dc.contributor.affiliatedAuthorLee, Seung Jong-
dc.contributor.affiliatedAuthorJung, Il Young-
dc.citation.volume35-
dc.citation.number6-
dc.citation.startPage453-
dc.citation.endPage460-
dc.identifier.bibliographicCitationJournal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.35(6) : 453-460, 2010-
dc.identifier.rimsid35041-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.