712 939

Cited 0 times in

웨이브프론트 방식을 이용한 라섹 수술 시 수술 전 다양한 굴절 검사의 정확도 비교

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author안현석-
dc.date.accessioned2015-04-23T17:16:09Z-
dc.date.available2015-04-23T17:16:09Z-
dc.date.issued2010-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/102141-
dc.description.abstractPURPOSE: To predict the accuracy of preoperative refractive error measurement methods in wavefront-guided laser-assisted subepithelial keratectomy (LASEK) surgery and to formulate a nomogram for satisfactory surgical results. METHODS: The medical records of 30 patients (57 eyes) who had undergone wavefront-guided LASEK were reviewed. The ideal surgical ablation amount was defined as the sum of the real surgical ablation amount and the remaining refractive errors. Comparison between the ideal surgical ablation amount and preoperative refractive errors was made using autorefraction, manifest refraction, cycloplegic refraction, postcycloplegic refraction, wavescan, and iTrace aberrometer measurements. RESULTS: The refractive errors measured by the postcycloplegic refraction showed the closest relation with the ideal surgical amount, and the nomogram based on this refraction correlated statistically significantly with the ideal surgical ablation amount. The refractive error using the wavescan also showed more accurate refractive measurements than the autorefractor and iTrace aberrometer. CONCLUSIONS: Accurate manifest refraction immediately before surgery is the most important in determining the ablation amount. Additionally, the refractive errors measured with the wavescan, which is an aberrometer used for wavefront-guided LASEK, showed a minimal amount of errors. After reviewing the results, the nomogram based on these 2 methods can be concluded to possibly contribute to an increase in the accuracy of surgery-
dc.description.statementOfResponsibilityopen-
dc.format.extent1196~1202-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title웨이브프론트 방식을 이용한 라섹 수술 시 수술 전 다양한 굴절 검사의 정확도 비교-
dc.title.alternativeComparison of the Refractive Error Measurement Using Different Methods in Wavefront-Guided LASEK-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor안지민-
dc.contributor.googleauthor안현석-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2010.51.9.1196-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA02272-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordiTrace aberrometer-
dc.subject.keywordNomogram-
dc.subject.keywordPostcycloplegic refraction-
dc.subject.keywordWavefront-guided LASEK-
dc.subject.keywordWavescan-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameAhn, Hyun Seok-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorAhn, Hyun Seok-
dc.citation.volume51-
dc.citation.number9-
dc.citation.startPage1196-
dc.citation.endPage1202-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.51(9) : 1196-1202, 2010-
dc.identifier.rimsid49972-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.