Cited 16 times in
Airway scope vs Macintosh laryngoscope during chest compressions on a fresh cadaver model
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 조준호 | - |
dc.contributor.author | 정성필 | - |
dc.contributor.author | 정현수 | - |
dc.date.accessioned | 2015-04-23T17:06:32Z | - |
dc.date.available | 2015-04-23T17:06:32Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 0735-6757 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/101836 | - |
dc.description.abstract | PURPOSES: This study compared the Airway scope (AWS) to the Macintosh laryngoscope (ML) during chest compressions on a fresh cadaver. METHODS: This was a prospective crossover study. The participants who had experiences with AWS were excluded. The participants intubated with randomly assigned AWS or ML on a fresh cadaver during chest compressions. Primary outcome were as follows: time to intubation, ease of intubation (rated by using the visual analog scale [VAS]), and intubation success rate. RESULTS: Twenty-five were enrolled. Median time of intubation was similar between the AWS and ML (AWS, 18.5 seconds vs ML, 18.3 seconds; P = .112). The median VAS of AWS and ML were 3.0 and 2.0, respectively (P = .023). There was no failure of intubation. However, participants replied that the AWS was more difficult to use than the ML. CONCLUSION: Considering the lack of experience with the AWS, AWS could be an alternative intubation device during chest compressions after practices with AWS. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 741~744 | - |
dc.relation.isPartOf | AMERICAN JOURNAL OF EMERGENCY MEDICINE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Cadaver | - |
dc.subject.MESH | Cardiopulmonary Resuscitation/instrumentation* | - |
dc.subject.MESH | Clinical Competence | - |
dc.subject.MESH | Cross-Over Studies | - |
dc.subject.MESH | Equipment Design | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Heart Massage* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intubation, Intratracheal/instrumentation* | - |
dc.subject.MESH | Laryngoscopes* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Models, Cardiovascular | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Time Factors | - |
dc.title | Airway scope vs Macintosh laryngoscope during chest compressions on a fresh cadaver model | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Emergency Medicine (응급의학) | - |
dc.contributor.googleauthor | Junho Cho | - |
dc.contributor.googleauthor | Hyun Soo Chung | - |
dc.contributor.googleauthor | Sung Pil Chung | - |
dc.contributor.googleauthor | Young-Min Kim | - |
dc.contributor.googleauthor | Young Soon Cho | - |
dc.identifier.doi | 10.1016/j.ajem.2009.06.021 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A03911 | - |
dc.contributor.localId | A03625 | - |
dc.relation.journalcode | J00079 | - |
dc.identifier.eissn | 1532-8171 | - |
dc.identifier.pmid | 20637394 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0735675709003143 | - |
dc.contributor.alternativeName | Cho, Jun Ho | - |
dc.contributor.alternativeName | Chung, Sung Pil | - |
dc.contributor.alternativeName | Chung, Hyun Soo | - |
dc.contributor.affiliatedAuthor | Cho, Jun Ho | - |
dc.contributor.affiliatedAuthor | Chung, Sung Pil | - |
dc.citation.volume | 28 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 741 | - |
dc.citation.endPage | 744 | - |
dc.identifier.bibliographicCitation | AMERICAN JOURNAL OF EMERGENCY MEDICINE, Vol.28(6) : 741-744, 2010 | - |
dc.identifier.rimsid | 54641 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.