0 575

Cited 59 times in

Spectral-domain optical coherence tomography for detection of localized retinal nerve fiber layer defects in patients with open-angle glaucoma. Kim NR, Lee ES, Seong GJ, Choi EH, Hong S, Kim CY.

DC Field Value Language
dc.contributor.author김나래-
dc.contributor.author김찬윤-
dc.contributor.author성공제-
dc.contributor.author이은석-
dc.contributor.author최은희-
dc.contributor.author홍사민-
dc.date.accessioned2015-04-23T16:59:51Z-
dc.date.available2015-04-23T16:59:51Z-
dc.date.issued2010-
dc.identifier.issn0003-9950-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/101630-
dc.description.abstractOBJECTIVE: To evaluate and compare time-domain (Stratus) and spectral-domain (Cirrus; both Carl Zeiss Meditec, Dublin, California) optical coherence tomography (OCT) for the detection of localized retinal nerve fiber layer (RNFL) defects in patients with open-angle glaucoma. METHODS: Patients with localized RNFL defects and age-matched normal control participants were consecutively enrolled from July 1 to December 31, 2008. Sixty-six eyes from 66 patients and 66 eyes from 66 normal controls were imaged with Stratus OCT (fast RNFL scan mode) and Cirrus OCT (optic disc cube mode). The ability to detect the RNFL defect by using quadrant clock-hour maps from both OCTs and a Cirrus OCT deviation map were compared with red-free RNFL photography, which is the criterion standard for visualizing RNFL defects. RESULTS: The Cirrus OCT deviation map exhibited significantly higher overall sensitivity (92.42%) in detecting the RNFL defects compared with the other maps, which were derived from a 3.46-mm-diameter peripapillary cross-sectional RNFL scan of both OCTs (P < .001). The Cirrus OCT quadrant map had a higher specificity; however, it was not statistically significant (P = .07). Compared with the other maps, the Cirrus OCT derivation map had the lowest cutoff angle for the width (10.69°) of the RNFL defect. CONCLUSIONS: The deviation map from Cirrus OCT was more sensitive in detecting RNFL defects than the clock-hour and quadrant maps derived from cross-sectional peripapillary RNFL measurements by Stratus and Cirrus OCTs. The ability to detect localized RNFL defects on clock-hour or quadrant RNFL maps did not significantly differ between Stratus OCT and Cirrus OCT.-
dc.description.statementOfResponsibilityopen-
dc.format.extent1121~1128-
dc.relation.isPartOfARCHIVES OF OPHTHALMOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHFemale-
dc.subject.MESHGlaucoma, Open-Angle/diagnosis*-
dc.subject.MESHHumans-
dc.subject.MESHIntraocular Pressure-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHNerve Fibers/pathology*-
dc.subject.MESHOptic Disk/pathology*-
dc.subject.MESHOptic Nerve Diseases/diagnosis*-
dc.subject.MESHROC Curve-
dc.subject.MESHRetinal Ganglion Cells/pathology*-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHTime Factors-
dc.subject.MESHTomography, Optical Coherence*-
dc.titleSpectral-domain optical coherence tomography for detection of localized retinal nerve fiber layer defects in patients with open-angle glaucoma. Kim NR, Lee ES, Seong GJ, Choi EH, Hong S, Kim CY.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorNa Rae Kim-
dc.contributor.googleauthorEun Suk Lee-
dc.contributor.googleauthorGong Je Seong-
dc.contributor.googleauthorEun Hee Choi-
dc.contributor.googleauthorSamin Hong-
dc.contributor.googleauthorChan Yun Kim-
dc.identifier.doi10.1001/archophthalmol.2010.204-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00347-
dc.contributor.localIdA01035-
dc.contributor.localIdA01946-
dc.contributor.localIdA04163-
dc.contributor.localIdA04395-
dc.contributor.localIdA03036-
dc.relation.journalcodeJ00224-
dc.identifier.eissn1538-3601-
dc.identifier.pmid20837794-
dc.identifier.urlhttp://archopht.jamanetwork.com/article.aspx?articleid=1103761-
dc.contributor.alternativeNameKim, Na Rae-
dc.contributor.alternativeNameKim, Chan Yun-
dc.contributor.alternativeNameSeong, Gong Je-
dc.contributor.alternativeNameLee, Eun Suk-
dc.contributor.alternativeNameChoi, Eun Hee-
dc.contributor.alternativeNameHong, Sa Min-
dc.contributor.affiliatedAuthorKim, Na Rae-
dc.contributor.affiliatedAuthorKim, Chan Yun-
dc.contributor.affiliatedAuthorSeong, Gong Je-
dc.contributor.affiliatedAuthorChoi, Eun Hee-
dc.contributor.affiliatedAuthorHong, Sa Min-
dc.contributor.affiliatedAuthorLee, Eun Suk-
dc.citation.volume128-
dc.citation.number9-
dc.citation.startPage1121-
dc.citation.endPage1128-
dc.identifier.bibliographicCitationARCHIVES OF OPHTHALMOLOGY , Vol.128(9) : 1121-1128, 2010-
dc.identifier.rimsid40128-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Biomedical Systems Informatics (의생명시스템정보학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.