4 627

Cited 15 times in

Effect of conical configuration of fixture on the maintenance of marginal bone level: preliminary results at 1 year of function

DC Field Value Language
dc.contributor.author김종관-
dc.contributor.author문익상-
dc.contributor.author박광호-
dc.contributor.author이동원-
dc.date.accessioned2015-04-23T16:39:47Z-
dc.date.available2015-04-23T16:39:47Z-
dc.date.issued2010-
dc.identifier.issn0905-7161-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/100992-
dc.description.abstractOBJECTIVES: To evaluate and to compare the effect of the conical neck design on marginal bone loss around the fixtures, when both implants were provided with micro-threads to the top of the fixture. MATERIALS AND METHODS: Two types of implant, one with a straight shape (S) and the other with a conical neck design (C) provided with a retentive element to the top of the fixture, were placed adjacent to each other in the partially edentulous areas of 12 patients. Bone loss around each implant was analyzed after 1 year of functional loading. The bone losses after loading were compared using Wilcoxon's signed-rank test. RESULTS: The mean marginal bone losses (S, 0.05 + or - 0.09 mm; C, 0.07 + or - 0.14 mm) were not statistically significant between the two groups (P=0.578). CONCLUSIONS: There was no significant difference between conical and straight neck implants in terms of marginal bone loss after 1 year of loading.-
dc.description.statementOfResponsibilityopen-
dc.format.extent439~444-
dc.relation.isPartOfCLINICAL ORAL IMPLANTS RESEARCH-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAlveolar Bone Loss/prevention & control*-
dc.subject.MESHDental Implantation, Endosseous*-
dc.subject.MESHDental Implants*-
dc.subject.MESHDental Prosthesis Design*-
dc.subject.MESHDental Prosthesis, Implant-Supported-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHProspective Studies-
dc.subject.MESHStatistics, Nonparametric-
dc.titleEffect of conical configuration of fixture on the maintenance of marginal bone level: preliminary results at 1 year of function-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Oral and Maxillofacial Surgery (구강악안면외과학)-
dc.contributor.googleauthorJung-Joo Kim-
dc.contributor.googleauthorDong-Won Lee-
dc.contributor.googleauthorChong-Kwan Kim-
dc.contributor.googleauthorKwang-Ho Park-
dc.contributor.googleauthorIk-Sang Moon-
dc.identifier.doi10.1111/j.1600-0501.2009.01871.x-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01373-
dc.contributor.localIdA01435-
dc.contributor.localIdA02728-
dc.contributor.localIdA00914-
dc.relation.journalcodeJ00600-
dc.identifier.eissn1600-0501-
dc.identifier.pmid20443797-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1111/j.1600-0501.2009.01871.x/abstract-
dc.subject.keywordconical neck-
dc.subject.keywordimplant-
dc.subject.keywordmarginal bone-
dc.subject.keywordmicro‐thread-
dc.subject.keywordstraight neck-
dc.contributor.alternativeNameKim, Chong Kwan-
dc.contributor.alternativeNameMoon, Ik Sang-
dc.contributor.alternativeNamePark, Kwang Ho-
dc.contributor.alternativeNameLee, Dong Won-
dc.contributor.affiliatedAuthorMoon, Ik Sang-
dc.contributor.affiliatedAuthorPark, Kwang Ho-
dc.contributor.affiliatedAuthorLee, Dong Won-
dc.contributor.affiliatedAuthorKim, Chong Kwan-
dc.citation.volume21-
dc.citation.number4-
dc.citation.startPage439-
dc.citation.endPage444-
dc.identifier.bibliographicCitationCLINICAL ORAL IMPLANTS RESEARCH, Vol.21(4) : 439-444, 2010-
dc.identifier.rimsid54495-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Oral and Maxillofacial Surgery (구강악안면외과학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.