0 190

Cited 1 times in

Fully automatic quantification of transient severe respiratory motion artifact of gadoxetate disodium-enhanced MRI during arterial phase

Authors
 Jinseong Jang  ;  Yong Eun Chung  ;  Sungwon Kim  ;  Dosik Hwang 
Citation
 MEDICAL PHYSICS, Vol.49(11) : 7247-7261, 2022-11 
Journal Title
MEDICAL PHYSICS
ISSN
 0094-2405 
Issue Date
2022-11
MeSH
Automation ; Humans ; Magnetic Resonance Imaging* ; Respiration
Keywords
gadoxetate disodium ; image quality assessment ; motion artifact ; transient severe respiratory motion
Abstract
Purpose: It is important to fully automate the evaluation of gadoxetate disodium-enhanced arterial phase images because the efficient quantification of transient severe motion artifacts can be used in a variety of applications. Our study proposes a fully automatic evaluation method of motion artifacts during the arterial phase of gadoxetate disodium-enhanced MR imaging.

Methods: The proposed method was based on the construction of quality-aware features to represent the motion artifact using MR image statistics and multidirectional filtered coefficients. Using the quality-aware features, the method calculated quantitative quality scores of gadoxetate disodium-enhanced images fully automatically. The performance of our proposed method, as well as two other methods, was acquired by correlating scores against subjective scores from radiologists based on the 5-point scale and binary evaluation. The subjective scores evaluated by two radiologists were severity scores of motion artifacts in the evaluation set on a scale of 1 (no motion artifacts) to 5 (severe motion artifacts).

Results: Pearson's linear correlation coefficient (PLCC) and Spearman's rank-ordered correlation coefficient (SROCC) values of our proposed method against the subjective scores were 0.9036 and 0.9057, respectively, whereas the PLCC values of two other methods were 0.6525 and 0.8243, and the SROCC values were 0.6070 and 0.8348. Also, in terms of binary quantification of transient severe respiratory motion, the proposed method achieved 0.9310 sensitivity, 0.9048 specificity, and 0.9200 accuracy, whereas the other two methods achieved 0.7586, 0.8996 sensitivities, 0.8098, 0.8905 specificities, and 0.9200, 0.9048 accuracies CONCLUSIONS: This study demonstrated the high performance of the proposed automatic quantification method in evaluating transient severe motion artifacts in arterial phase images.
Full Text
https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.15831
DOI
10.1002/mp.15831
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sungwon(김성원) ORCID logo https://orcid.org/0000-0001-5455-6926
Chung, Yong Eun(정용은) ORCID logo https://orcid.org/0000-0003-0811-9578
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/193260
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links