0 200

Cited 1 times in

Fully automatic quantification of transient severe respiratory motion artifact of gadoxetate disodium-enhanced MRI during arterial phase

DC Field Value Language
dc.contributor.author김성원-
dc.contributor.author정용은-
dc.date.accessioned2023-03-10T01:37:01Z-
dc.date.available2023-03-10T01:37:01Z-
dc.date.issued2022-11-
dc.identifier.issn0094-2405-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/193260-
dc.description.abstractPurpose: It is important to fully automate the evaluation of gadoxetate disodium-enhanced arterial phase images because the efficient quantification of transient severe motion artifacts can be used in a variety of applications. Our study proposes a fully automatic evaluation method of motion artifacts during the arterial phase of gadoxetate disodium-enhanced MR imaging. Methods: The proposed method was based on the construction of quality-aware features to represent the motion artifact using MR image statistics and multidirectional filtered coefficients. Using the quality-aware features, the method calculated quantitative quality scores of gadoxetate disodium-enhanced images fully automatically. The performance of our proposed method, as well as two other methods, was acquired by correlating scores against subjective scores from radiologists based on the 5-point scale and binary evaluation. The subjective scores evaluated by two radiologists were severity scores of motion artifacts in the evaluation set on a scale of 1 (no motion artifacts) to 5 (severe motion artifacts). Results: Pearson's linear correlation coefficient (PLCC) and Spearman's rank-ordered correlation coefficient (SROCC) values of our proposed method against the subjective scores were 0.9036 and 0.9057, respectively, whereas the PLCC values of two other methods were 0.6525 and 0.8243, and the SROCC values were 0.6070 and 0.8348. Also, in terms of binary quantification of transient severe respiratory motion, the proposed method achieved 0.9310 sensitivity, 0.9048 specificity, and 0.9200 accuracy, whereas the other two methods achieved 0.7586, 0.8996 sensitivities, 0.8098, 0.8905 specificities, and 0.9200, 0.9048 accuracies CONCLUSIONS: This study demonstrated the high performance of the proposed automatic quantification method in evaluating transient severe motion artifacts in arterial phase images.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherPublished for the American Assn. of Physicists in Medicine by the American Institute of Physics.-
dc.relation.isPartOfMEDICAL PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAutomation-
dc.subject.MESHHumans-
dc.subject.MESHMagnetic Resonance Imaging*-
dc.subject.MESHRespiration-
dc.titleFully automatic quantification of transient severe respiratory motion artifact of gadoxetate disodium-enhanced MRI during arterial phase-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthorJinseong Jang-
dc.contributor.googleauthorYong Eun Chung-
dc.contributor.googleauthorSungwon Kim-
dc.contributor.googleauthorDosik Hwang-
dc.identifier.doi10.1002/mp.15831-
dc.contributor.localIdA05309-
dc.contributor.localIdA03662-
dc.relation.journalcodeJ02206-
dc.identifier.eissn2473-4209-
dc.identifier.pmid35754384-
dc.identifier.urlhttps://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.15831-
dc.subject.keywordgadoxetate disodium-
dc.subject.keywordimage quality assessment-
dc.subject.keywordmotion artifact-
dc.subject.keywordtransient severe respiratory motion-
dc.contributor.alternativeNameKim, Sungwon-
dc.contributor.affiliatedAuthor김성원-
dc.contributor.affiliatedAuthor정용은-
dc.citation.volume49-
dc.citation.number11-
dc.citation.startPage7247-
dc.citation.endPage7261-
dc.identifier.bibliographicCitationMEDICAL PHYSICS, Vol.49(11) : 7247-7261, 2022-11-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.