0 400

Cited 2 times in

Clinical implication of neointimal burden in in-stent restenosis treated with drug-coated balloon

Authors
 Jung-Hee Lee  ;  Ung Kim  ;  Jung-Sun Kim  ;  Sung-Jin Hong  ;  Chul-Min Ahn  ;  Byeong-Keuk Kim  ;  Young-Guk Ko  ;  Donghoon Choi  ;  Myeong-Ki Hong  ;  Yangsoo Jang 
Citation
 CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Vol.98(3) : 493-502, 2021-09 
Journal Title
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
ISSN
 1522-1946 
Issue Date
2021-09
MeSH
Coronary Angiography ; Coronary Restenosis* / diagnostic imaging ; Coronary Restenosis* / etiology ; Drug-Eluting Stents* ; Humans ; Percutaneous Coronary Intervention* ; Pharmaceutical Preparations* ; Treatment Outcome ; Substances
Keywords
drug-eluting balloon ; in-stent restenosis ; neointima ; optical coherence tomography ; treatment outcome
Abstract
Background: Although drug-coated balloon (DCB) angioplasty is a well-established drug-eluting stent (DES) in-stent restenosis (ISR) strategy, there are minimal data regarding the association of neointimal burden on optical coherence tomography (OCT) before and after DCB and adverse clinical events. This study aimed to investigate the clinical impact of neointimal burden measured with OCT in patients with DES ISR after DCB angioplasty.

Methods: From 2010 through 2013, a total of 122 patients with 122 ISR lesions were treated with DCB, which was preceded and followed by OCT examination. Major adverse cardiac events (MACE, a composite occurrence of cardiovascular cardiac death, nonfatal myocardial infarction [MI], or target lesion revascularization [TLR]) were evaluated.

Results: MACE occurred in 27 patients (4 nonfatal MIs and 23 TLRs) during the follow-up (median: 55.3 months, interquartile range 43.1-66.0). The mean lumen area was significantly smaller (3.21 ± 2.42 mm2 vs. 4.80 ± 2.53 mm2 , p = .005) and the mean percentage of neointimal volume derived by OCT was greater (49.3 ± 9.2% vs. 38.3 ± 17.5%, p = .006) in patients with MACE before DCB angioplasty. The pre-procedural mean percentage of neointimal volume (cut-off 50%, area under the receiver operating characteristic [ROC] curve = 0.644, 95% confidence interval [CI] = 0.531-0.758, p = .022) and post-procedural mean percentage of neointimal volume (cut-off 25%, area under ROC curve = 0.659, 95% CI = 0.546-0.773, p = .012) were identified as significant parameters to predict MACE.

Conclusion: The OCT-derived mean percentages of neointimal volume before and after DCB angioplasty can be important parameters for predicting future MACE in patients with DES ISR.
Full Text
https://onlinelibrary.wiley.com/doi/10.1002/ccd.29211
DOI
10.1002/ccd.29211
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Ahn, Chul-Min(안철민) ORCID logo https://orcid.org/0000-0002-7071-4370
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
Hong, Sung Jin(홍성진) ORCID logo https://orcid.org/0000-0003-4893-039X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/190784
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links