0 682

Cited 26 times in

Iris synechia after laser goniopuncture in a patient having deep sclerectomy with a collagen implant

Authors
 Chan Y. Kim  ;  Young J. Hong  ;  Gong J. Seong  ;  Hyoung J. Koh  ;  Sung S. Kim 
Citation
 JOURNAL OF CATARACT AND REFRACTIVE SURGERY, Vol.28(5) : 900-902, 2002 
Journal Title
JOURNAL OF CATARACT AND REFRACTIVE SURGERY
ISSN
 0886-3350 
Issue Date
2002
MeSH
Adult ; Collagen* ; Corneal Diseases/etiology* ; Filtering Surgery ; Glaucoma, Open-Angle/surgery ; Gonioscopy ; Humans ; Intraocular Pressure ; IrisDiseases/etiology* ; LaserTherapy/adverse effects* ; Male ; Prosthesis Implantation ; Punctures/adverse effects* ; Sclerostomy* ; Tissue Adhesions/etiology
Abstract
Neodymium:YAG (Nd:YAG) goniopuncture is an efficient and safe treatment for low filtration through the trabeculo-Descemet’s membrane after deep sclerectomy with a collagen implant (DSCI). The only reported complication of this procedure is choroidal detachment. However, we found an iris synechia in a patient whose intraocular pressure (IOP) was elevated again 1 month after Nd:YAG goniopuncture. Synechiolysis and peripheral iridectomy with Nd:YAG and argon lasers effectively removed the iris synechia, and IOP immediately dropped to the normal range. We believe that iris synechia is a potential complication that may cause elevated IOP after laser goniopuncture in patients having DSCI.
Full Text
http://www.sciencedirect.com/science/article/pii/S0886335001013074
DOI
10.1016/S0886-3350(01)01307-4
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Koh, Hyoung Jun(고형준) ORCID logo https://orcid.org/0000-0002-5932-8516
Kim, Chan Yun(김찬윤) ORCID logo https://orcid.org/0000-0002-8373-9999
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/144219
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links