Cited 26 times in
Iris synechia after laser goniopuncture in a patient having deep sclerectomy with a collagen implant
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고형준 | - |
dc.contributor.author | 김찬윤 | - |
dc.contributor.author | 성공제 | - |
dc.date.accessioned | 2016-05-16T11:17:25Z | - |
dc.date.available | 2016-05-16T11:17:25Z | - |
dc.date.issued | 2002 | - |
dc.identifier.issn | 0886-3350 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/144219 | - |
dc.description.abstract | Neodymium:YAG (Nd:YAG) goniopuncture is an efficient and safe treatment for low filtration through the trabeculo-Descemet’s membrane after deep sclerectomy with a collagen implant (DSCI). The only reported complication of this procedure is choroidal detachment. However, we found an iris synechia in a patient whose intraocular pressure (IOP) was elevated again 1 month after Nd:YAG goniopuncture. Synechiolysis and peripheral iridectomy with Nd:YAG and argon lasers effectively removed the iris synechia, and IOP immediately dropped to the normal range. We believe that iris synechia is a potential complication that may cause elevated IOP after laser goniopuncture in patients having DSCI. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 900~902 | - |
dc.relation.isPartOf | JOURNAL OF CATARACT AND REFRACTIVE SURGERY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Collagen* | - |
dc.subject.MESH | Corneal Diseases/etiology* | - |
dc.subject.MESH | Filtering Surgery | - |
dc.subject.MESH | Glaucoma, Open-Angle/surgery | - |
dc.subject.MESH | Gonioscopy | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intraocular Pressure | - |
dc.subject.MESH | IrisDiseases/etiology* | - |
dc.subject.MESH | LaserTherapy/adverse effects* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Prosthesis Implantation | - |
dc.subject.MESH | Punctures/adverse effects* | - |
dc.subject.MESH | Sclerostomy* | - |
dc.subject.MESH | Tissue Adhesions/etiology | - |
dc.title | Iris synechia after laser goniopuncture in a patient having deep sclerectomy with a collagen implant | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Chan Y. Kim | - |
dc.contributor.googleauthor | Young J. Hong | - |
dc.contributor.googleauthor | Gong J. Seong | - |
dc.contributor.googleauthor | Hyoung J. Koh | - |
dc.contributor.googleauthor | Sung S. Kim | - |
dc.identifier.doi | 10.1016/S0886-3350(01)01307-4 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00152 | - |
dc.contributor.localId | A01035 | - |
dc.contributor.localId | A01946 | - |
dc.relation.journalcode | J01299 | - |
dc.identifier.eissn | 1873-4502 | - |
dc.identifier.pmid | 11978477 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0886335001013074 | - |
dc.contributor.alternativeName | Koh, Hyoung Jun | - |
dc.contributor.alternativeName | Kim, Chan Yun | - |
dc.contributor.alternativeName | Seong, Gong Je | - |
dc.contributor.affiliatedAuthor | Koh, Hyoung Jun | - |
dc.contributor.affiliatedAuthor | Kim, Chan Yun | - |
dc.contributor.affiliatedAuthor | Seong, Gong Je | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 28 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 900 | - |
dc.citation.endPage | 902 | - |
dc.identifier.bibliographicCitation | JOURNAL OF CATARACT AND REFRACTIVE SURGERY, Vol.28(5) : 900-902, 2002 | - |
dc.identifier.rimsid | 56692 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.