1 542

Cited 24 times in

The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis

Authors
 Jung-Sun Kim  ;  Jinyong Ha  ;  Byeong-Keuk Kim  ;  Dong-Ho Shin  ;  Young-Guk Ko  ;  Donghoon Choi  ;  Yangsoo Jang  ;  Myeong-Ki Hong 
Citation
 JACC-CARDIOVASCULAR INTERVENTIONS, Vol.7(6) : 641-651, 2014 
Journal Title
JACC-CARDIOVASCULAR INTERVENTIONS
ISSN
 1936-8798 
Issue Date
2014
MeSH
Coronary Artery Disease/diagnosis ; Coronary Artery Disease/surgery* ; Coronary Vessels/pathology* ; Coronary Vessels/surgery ; Drug-Eluting Stents* ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Prosthesis Design ; Reproducibility of Results ; Time Factors ; Tomography, Optical Coherence/methods*
Keywords
drug-eluting stent ; malapposition ; optical coherence tomography ; stent coverage
Abstract
OBJECTIVES: This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis.
BACKGROUND:Tracking the fate of interested regions of struts at different time points has not been investigated.
METHODS:Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus- (n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared.
RESULTS:The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001).
CONCLUSIONS:The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of Dyslipidemia and Hypertension and the Types of Implanted Drug-Eluting Stents; NCT01502904).
Full Text
http://www.sciencedirect.com/science/article/pii/S1936879814006025
DOI
10.1016/j.jcin.2013.12.205
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Shin, Dong Ho(신동호) ORCID logo https://orcid.org/0000-0002-7874-5542
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/99210
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links