3 685

Cited 11 times in

The stability following advancement genioplasty with biodegradable screw fixation.

DC Field Value Language
dc.contributor.author박형식-
dc.contributor.author정영수-
dc.contributor.author정휘동-
dc.date.accessioned2015-01-06T16:38:25Z-
dc.date.available2015-01-06T16:38:25Z-
dc.date.issued2014-
dc.identifier.issn0266-4356-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/98481-
dc.description.abstractThe purpose of this study was to compare postoperative stability using biodegradable screws with that of metal plates for fixation of advancement genioplasty. We studied patients who had advancement genioplasty alone or at the same time as other orthognathic surgery including mandibular setback. We assessed the lateral cephalographs at different time points (preoperatively, and 7 days, 3 months, 6 months, and 12 months postoperatively). A total of 54 patients were enrolled and 27 patients were assigned to each group. The position of pogonion was stable 12 months postoperatively, and the amount of skeletal advancement was reflected in soft tissue close to 100%. There were no clinical differences between biodegradable screws and conventional metal plates used for fixation. Biodegradable fixation for advancement genioplasty is a good option for patients who would require a second operation for removal of the plates.-
dc.description.statementOfResponsibilityopen-
dc.format.extent363~368-
dc.relation.isPartOfBRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAbsorbable Implants*-
dc.subject.MESHAlloys/chemistry-
dc.subject.MESHAnatomic Landmarks/pathology-
dc.subject.MESHBiocompatible Materials/chemistry-
dc.subject.MESHBone Plates-
dc.subject.MESHBone Screws*-
dc.subject.MESHCephalometry/methods-
dc.subject.MESHChin/pathology*-
dc.subject.MESHFemale-
dc.subject.MESHFollow-Up Studies-
dc.subject.MESHGenioplasty/instrumentation*-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMalocclusion, Angle Class I/surgery-
dc.subject.MESHMalocclusion, Angle Class III/surgery-
dc.subject.MESHMandible/pathology-
dc.subject.MESHMandible/surgery-
dc.subject.MESHOrthognathic Surgical Procedures/methods-
dc.subject.MESHPolyesters/chemistry-
dc.subject.MESHTreatment Outcome-
dc.subject.MESHYoung Adult-
dc.titleThe stability following advancement genioplasty with biodegradable screw fixation.-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Oral and Maxillofacial Surgery (구강악안면외과학)-
dc.contributor.googleauthorGyu-Tae Lee-
dc.contributor.googleauthorHwi-Dong Jung-
dc.contributor.googleauthorSang Yoon Kim-
dc.contributor.googleauthorHyung-Sik Park-
dc.contributor.googleauthorYoung-Soo Jung-
dc.identifier.doi10.1016/j.bjoms.2013.12.009-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01755-
dc.contributor.localIdA03655-
dc.contributor.localIdA03792-
dc.relation.journalcodeJ00413-
dc.identifier.eissn1532-1940-
dc.identifier.pmid24485052-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S026643561300538X-
dc.subject.keywordAdvancement genioplasty-
dc.subject.keywordBiodegradable fixation-
dc.subject.keywordRetrogenia-
dc.contributor.alternativeNamePark, Hyung Sik-
dc.contributor.alternativeNameJung, Young Soo-
dc.contributor.alternativeNameJung, Hwi Dong-
dc.contributor.affiliatedAuthorPark, Hyung Sik-
dc.contributor.affiliatedAuthorJung, Young Soo-
dc.contributor.affiliatedAuthorJung, Hwi Dong-
dc.rights.accessRightsfree-
dc.citation.volume52-
dc.citation.number4-
dc.citation.startPage363-
dc.citation.endPage368-
dc.identifier.bibliographicCitationBRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, Vol.52(4) : 363-368, 2014-
dc.identifier.rimsid57617-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Oral and Maxillofacial Surgery (구강악안면외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.