Cited 116 times in
Incidences, Predictors, and Clinical Outcomes of Acute and Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고영국 | - |
dc.contributor.author | 김병극 | - |
dc.contributor.author | 김중선 | - |
dc.contributor.author | 신동호 | - |
dc.contributor.author | 임의 | - |
dc.contributor.author | 장양수 | - |
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 홍명기 | - |
dc.date.accessioned | 2015-01-06T16:27:42Z | - |
dc.date.available | 2015-01-06T16:27:42Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 1941-7640 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/98148 | - |
dc.description.abstract | BACKGROUND: We investigated the incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography (OCT) after drug-eluting stent implantation. METHODS AND RESULTS: We analyzed the OCT images from 351 patients with 356 lesions who received poststent and follow-up OCT examinations. Acute stent malapposition was observed in 62% of lesions. Approximately half of the acute stent malappositions were located within the edges of the stents. Severe diameter stenosis, calcified lesions, and long stents were independent predictors of acute stent malapposition. Follow-up OCT examinations were performed 175±60 days after drug-eluting stent implantation. Thirty-one percent of lesions with acute stent malapposition remained malapposed (late-persistent stent malapposition) and were typically (72%) located within the edges of the stent. The location within the stent edges and the volume of acute stent malapposition were independent predictors of late-persistent stent malapposition. Acute stent malapposition with a volume >2.56 mm(3) differentiated late-persistent stent malapposition from resolved acute stent malapposition. Late-acquired stent malapposition was detected in 15% of all lesions and was usually (61%) located within the stent body. Late-acquired stent malapposition was more frequently associated with plaque/thrombus prolapse on poststent OCT images (70% versus 42%; P<0.001). Clinical events, including cardiovascular death, nonfatal myocardial infarction, and stent thrombosis, did not occur in patients with late stent malapposition during the follow-up period of 28.6±10.3 months after drug-eluting stent implantation. CONCLUSIONS: Acute, late-persistent, and late-acquired stent malapposition had relatively high incidences but different predictors. The clinical outcome of stent malapposition was favorable. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 88~96 | - |
dc.relation.isPartOf | CIRCULATION-CARDIOVASCULAR INTERVENTIONS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Biomarkers/metabolism | - |
dc.subject.MESH | Coronary Artery Disease/diagnosis* | - |
dc.subject.MESH | Coronary Artery Disease/surgery | - |
dc.subject.MESH | Drug-Eluting Stents/utilization* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Follow-Up Studies | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Incidence | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Prognosis | - |
dc.subject.MESH | Prosthesis Failure/etiology | - |
dc.subject.MESH | Prosthesis Implantation* | - |
dc.subject.MESH | Tomography, Optical Coherence* | - |
dc.subject.MESH | Treatment Outcome | - |
dc.subject.MESH | Vascular Calcification | - |
dc.title | Incidences, Predictors, and Clinical Outcomes of Acute and Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Eui Im | - |
dc.contributor.googleauthor | Byeong-Keuk Kim | - |
dc.contributor.googleauthor | Young-Guk Ko | - |
dc.contributor.googleauthor | Dong-Ho Shin | - |
dc.contributor.googleauthor | Jung-Sun Kim | - |
dc.contributor.googleauthor | Donghoon Choi | - |
dc.contributor.googleauthor | Yangsoo Jang | - |
dc.contributor.googleauthor | Myeong-Ki Hong | - |
dc.identifier.doi | 10.1161/CIRCINTERVENTIONS.113.000797 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00127 | - |
dc.contributor.localId | A00493 | - |
dc.contributor.localId | A00961 | - |
dc.contributor.localId | A02097 | - |
dc.contributor.localId | A03394 | - |
dc.contributor.localId | A03448 | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A04391 | - |
dc.relation.journalcode | J00539 | - |
dc.identifier.eissn | 1941-7632 | - |
dc.identifier.pmid | 24425586 | - |
dc.identifier.url | http://circinterventions.ahajournals.org/content/7/1/88.long | - |
dc.subject.keyword | coronary disease | - |
dc.subject.keyword | drug-eluting stents | - |
dc.subject.keyword | tomography, optical coherence | - |
dc.contributor.alternativeName | Ko, Young Guk | - |
dc.contributor.alternativeName | Kim, Byeong Keuk | - |
dc.contributor.alternativeName | Kim, Jung Sun | - |
dc.contributor.alternativeName | Shin, Dong Ho | - |
dc.contributor.alternativeName | Im, Eui | - |
dc.contributor.alternativeName | Jang, Yang Soo | - |
dc.contributor.alternativeName | Choi, Dong Hoon | - |
dc.contributor.alternativeName | Hong, Myeong Ki | - |
dc.contributor.affiliatedAuthor | Ko, Young Guk | - |
dc.contributor.affiliatedAuthor | Kim, Byeong Keuk | - |
dc.contributor.affiliatedAuthor | Kim, Jung Sun | - |
dc.contributor.affiliatedAuthor | Shin, Dong Ho | - |
dc.contributor.affiliatedAuthor | Im, Eui | - |
dc.contributor.affiliatedAuthor | Jang, Yang Soo | - |
dc.contributor.affiliatedAuthor | Choi, Dong Hoon | - |
dc.contributor.affiliatedAuthor | Hong, Myeong Ki | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 7 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 88 | - |
dc.citation.endPage | 96 | - |
dc.identifier.bibliographicCitation | CIRCULATION-CARDIOVASCULAR INTERVENTIONS, Vol.7(1) : 88-96, 2014 | - |
dc.identifier.rimsid | 50680 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.