dc.description.abstractBackground It is important to assess cardiac preload for management of patients undergoing off pump coronary artery bypass surgery (OPCAB). Recently, several studies have documented the good correlation between right ventricular end-diastolic volume index (RVEDVI) and stroke volume index (SVI), compared with cardiac filling pressures. However, none of these studies have evaluated relationship between predictors of preload and SVI measured with volumetric pulmonary artery catheter during OPCAB. The correlation of continuous RVEDVI and SVI measured with volumetric pulmonary artery catheter during OPCAB was evaluated in this study Methods Fifty three patients undergoing OPCAB were included. Hemodynamic parameters were measured 10 min after induction (T1), 10 min after Y-graft formation started (T2) and 10 min after sternum closure (T3). The correlation of parameters were assessed by simple linear regression. Results Central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) did not correlate with SVI during OPCAB. On the other hand, a statistically significant result was found between RVEDVI and SVI at T2 (r2 = 0.133, P = 0.007) and T3 (r2 = 0.380, P < 0.000). But RVEDVI and SVI were weakly correlated. And at T1, RVEDVI and SVI did not correlate. Conclusions RVEDVI is a more reliable predictor of preload compared to CVP and PAOP during OPCAB. But in post-induction period (T2), RVEDVI did not correlate with SVI.-
dc.description.statementOfResponsibilityopen-
dc.format.extent206~211-
dc.relation.isPartOfKOREAN JOURNAL OF ANESTHESIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title체외순환 없는 관상동맥우회술 중 지속적 우심실용적 감시가 가능한 폐동맥카테터로 측정한 전부하 지표들은 일회박출량지수를 반영하는가?-
dc.title.alternativeDoes predictors of preload measured from continuous right ventricular end-diastolic volume index monitored pulmonary artery catheter reflect stroke volume index in off pump coronary artery bypass?-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology (마취통증의학)-
dc.contributor.googleauthor이지연-
dc.contributor.googleauthor방서욱-
dc.contributor.googleauthor곽영란-
dc.contributor.googleauthor원영주-
dc.contributor.googleauthor이종화-
dc.contributor.googleauthor심재광-
dc.identifier.doi10.4097/kjae.2007.53.2.206-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00172-
dc.contributor.localIdA01785-
dc.contributor.localIdA02205-
dc.contributor.localIdA03154-
dc.contributor.localIdA03195-
dc.relation.journalcodeJ03189-
dc.identifier.eissn2005-7563-
dc.contributor.alternativeNameLee, Ji Yeon-
dc.contributor.alternativeNameKwak, Young Lan-
dc.contributor.alternativeNameBang, Sou Ouk-
dc.contributor.alternativeNameShim, Jae Kwang-
dc.contributor.alternativeNameLee, Jong Wha-
dc.contributor.affiliatedAuthorKwak, Young Lan-
dc.contributor.affiliatedAuthorBang, Sou Ouk-
dc.contributor.affiliatedAuthorShim, Jae Kwang-
dc.contributor.affiliatedAuthorLee, Jong Wha-
dc.contributor.affiliatedAuthorLee, Ji Yeon-
dc.rights.accessRightsfree-
dc.citation.volume53-
dc.citation.number2-
dc.citation.startPage206-
dc.citation.endPage211-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF ANESTHESIOLOGY, Vol.53(2) : 206-211, 2007-
dc.identifier.rimsid36926-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.