3 481

Cited 11 times in

Inter-comparison of 18F-FDG PET/CT standardized uptake values in Korea

DC Field Value Language
dc.contributor.author이종두-
dc.date.accessioned2014-12-20T17:52:08Z-
dc.date.available2014-12-20T17:52:08Z-
dc.date.issued2011-
dc.identifier.issn0969-8043-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/95408-
dc.description.abstractThe number of PET/CT tests for diagnosing and treating tumors are increasing every year, and thus it is considered necessary to compare PET/CT images among medical institutions or among different PET/CT systems within the same medical institution. We present to get the variation of standardized uptake values (SUV) among PET/CT systems, to derive an SUV calibration table that enables quantitative comparison of PET/CT systems, and to test the usefulness of the calibration table through comparing patient's SUV with the SUV calibration table. The correlation coefficients that inter-compared the calibration constants of normal patients and the calibration constants of the mean standardized uptake value with the calibration constants of the standardized uptake value of phantom are 0.88938 (P<0.0001).-
dc.description.statementOfResponsibilityopen-
dc.format.extent241~246-
dc.relation.isPartOfAPPLIED RADIATION AND ISOTOPES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHCarcinoma, Non-Small-Cell Lung/diagnostic imaging*-
dc.subject.MESHCarcinoma, Non-Small-Cell Lung/metabolism-
dc.subject.MESHFemale-
dc.subject.MESHFluorodeoxyglucose F18/pharmacokinetics*-
dc.subject.MESHHumans-
dc.subject.MESHKorea-
dc.subject.MESHLung Neoplasms/diagnostic imaging*-
dc.subject.MESHLung Neoplasms/metabolism-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPhantoms, Imaging-
dc.subject.MESHPositron-Emission Tomography/methods-
dc.subject.MESHRadiopharmaceuticals/pharmacokinetics*-
dc.subject.MESHTissue Distribution-
dc.subject.MESHTomography, X-Ray Computed/methods-
dc.subject.MESHYoung Adult-
dc.titleInter-comparison of 18F-FDG PET/CT standardized uptake values in Korea-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Nuclear Medicine (핵의학)-
dc.contributor.googleauthorHoon Hee Park-
dc.contributor.googleauthorDae Sung Park-
dc.contributor.googleauthorDae Cheol Kweon-
dc.contributor.googleauthorSang Bock Lee-
dc.contributor.googleauthorKi Baek Oh-
dc.contributor.googleauthorJong Doo Lee-
dc.contributor.googleauthorGye Hwan Jin-
dc.identifier.doi10.1016/j.apradiso.2010.09.011-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03138-
dc.relation.journalcodeJ00206-
dc.identifier.eissn1872-9800-
dc.identifier.pmid20933430-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0969804310003738-
dc.subject.keywordCalibration table-
dc.subject.keywordCorrelation coefficients-
dc.subject.keywordMulticentre trial-
dc.subject.keywordPET/CT-
dc.subject.keywordSUV-
dc.contributor.alternativeNameLee, Jong Doo-
dc.contributor.affiliatedAuthorLee, Jong Doo-
dc.rights.accessRightsnot free-
dc.citation.volume69-
dc.citation.number1-
dc.citation.startPage241-
dc.citation.endPage246-
dc.identifier.bibliographicCitationAPPLIED RADIATION AND ISOTOPES, Vol.69(1) : 241-246, 2011-
dc.identifier.rimsid48350-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.