Cited 2 times in
Influences of Geometric Configurations of Bypass Grafts on Hemodynamics in End-to-Side Anastomosis.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 권혁문 | - |
dc.date.accessioned | 2014-12-20T17:34:51Z | - |
dc.date.available | 2014-12-20T17:34:51Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 2233-601X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/94869 | - |
dc.description.abstract | BACKGROUND: Although considerable efforts have been made to improve the graft patency in coronary artery bypass surgery, the role of biomechanical factors remains underrecognized. The aim of this study is to investigate the influences of geometric configurations of the bypass graft on hemodynamic characteristics in relation to anastomosis. MATERIALS AND METHODS: The Numerical analysis focuses on understanding the flow patterns for different values of inlet and distal diameters and graft angles. The Blood flow field is treated as a two-dimensional incompressible laminar flow. A finite volume method is adopted for discretization of the governing equations. The Carreau model is employed as a constitutive equation for blood. In an attempt to obtain the optimal aorto-coronary bypass conditions, the blood flow characteristics are analyzed using in vitro models of the end-to-side anastomotic angles of 45degrees, 60degrees and 90degrees. To find the optimal graft configurations, the mass flow rates at the outlets of the four models are compared quantitatively. RESULTS: This study finds that Model 3, whose bypass diameter is the same as the inlet diameter of the stenosed coronary artery, delivers the largest amount of blood and the least pressure drop along the arteries. CONCLUSION: Biomechanical factors are speculated to contribute to the graft patency in coronary artery bypass grafting. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 89~98 | - |
dc.language | English | - |
dc.publisher | Korean Society for Thoracic and Cardiovascular Surgery | - |
dc.relation.isPartOf | Korean Journal of Thoracic and Cardiovascular Surgery | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Influences of Geometric Configurations of Bypass Grafts on Hemodynamics in End-to-Side Anastomosis. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Jae-Sung Choi | - |
dc.contributor.googleauthor | Sung Chul Hong | - |
dc.contributor.googleauthor | Hyuck Moon Kwon | - |
dc.contributor.googleauthor | Sang-Ho Suh | - |
dc.contributor.googleauthor | Jeong Sang Lee | - |
dc.identifier.doi | 10.5090/kjtcs.2011.44.2.89 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00260 | - |
dc.relation.journalcode | J02126 | - |
dc.identifier.eissn | 2093-6516 | - |
dc.identifier.pmid | 22263134 | - |
dc.subject.keyword | Anastomosis | - |
dc.subject.keyword | surgery | - |
dc.subject.keyword | Computer simulation | - |
dc.subject.keyword | Coronary artery bypass | - |
dc.subject.keyword | Hemodynamics | - |
dc.contributor.alternativeName | Kwon, Hyuck Moon | - |
dc.contributor.affiliatedAuthor | Kwon, Hyuck Moon | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 44 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 89 | - |
dc.citation.endPage | 98 | - |
dc.identifier.bibliographicCitation | Korean Journal of Thoracic and Cardiovascular Surgery, Vol.44(2) : 89-98, 2011 | - |
dc.identifier.rimsid | 27813 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.