Bilateral subthalamic deep brain stimulation using single track microelectrode recording

DC Field Value Language
dc.contributor.author김주평-
dc.contributor.author박영석-
dc.contributor.author장원석-
dc.contributor.author장진우-
dc.date.accessioned2014-12-20T17:34:35Z-
dc.date.available2014-12-20T17:34:35Z-
dc.date.issued2011-
dc.identifier.issn0001-6268-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94860-
dc.description.abstractBACKGROUND: Microelectrode recording (MER) is widely used during deep brain stimulation (DBS) procedures because MER can identify structural borders and eloquent structures, localize somatotopic arrangements, and provide an outline of the three-dimensional shapes of target nuclei. However, MER may cause intracranial hemorrhage. We preformed single track MER during DBS procedures, analyzed the accuracy of electrode positioning with MRI, and compared the amount of air and the potential risk of intracranial hemorrhage. METHOD: A total of 46 electrodes were placed in 23 patients who suffered from advanced Parkinson's disease and who underwent bilateral subthalamic nucleus DBS using single track MER. Each patient's Unified Parkinson's Disease Rating Scale (UPDRS) score and levo-dopa equivalent dosage (LED) were estimated pre- and postoperatively. The accuracy of electrode positioning and fontal air thickness was measured by a pre- or postoperative magnetic resonance imaging (MRI) merging technique. FINDINGS: The mean electrode positioning error was 0.92 mm (0.3-2.94 mm). The mean frontal air thickness on postoperative MRI was 3.85 mm (0-10.3 mm), which did not affect the electrode accuracy statistically (p = 0.730). A total of nine electrodes required repositioning after single-track MER because they affected microstimulation or because an abnormally short STN length was observed during MER. In this series, one patient suffered from an intracranial hemorrhage after surgery that appeared to be due to venous infarction rather than related to MER. CONCLUSIONS: Although MER can facilitate accurate positioning of electrodes, multi-track MER may increase the risk of intracranial hemorrhage. The accuracy of electrode positioning appears to be acceptable under single track MER during STN DBS with careful electrophysiological and neurological monitoring. The risk of intracranial hemorrhage appears to be minimal, especially in elderly patients with atrophic brains-
dc.description.statementOfResponsibilityopen-
dc.format.extent1087~1095-
dc.relation.isPartOfACTA NEUROCHIRURGICA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHDeep Brain Stimulation/adverse effects-
dc.subject.MESHDeep Brain Stimulation/instrumentation-
dc.subject.MESHDeep Brain Stimulation/methods*-
dc.subject.MESHElectrophysiology/instrumentation*-
dc.subject.MESHElectrophysiology/methods-
dc.subject.MESHElectrophysiology/trends-
dc.subject.MESHFemale-
dc.subject.MESHFunctional Laterality/physiology-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMicroelectrodes/adverse effects-
dc.subject.MESHMicroelectrodes/standards-
dc.subject.MESHParkinson Disease/therapy*-
dc.subject.MESHSubthalamic Nucleus/physiology*-
dc.titleBilateral subthalamic deep brain stimulation using single track microelectrode recording-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학)-
dc.contributor.googleauthorWon Seok Chang-
dc.contributor.googleauthorHae Yu Kim-
dc.contributor.googleauthorJoo Pyung Kim-
dc.contributor.googleauthorYoung Seok Park-
dc.contributor.googleauthorSang Sup Chung-
dc.contributor.googleauthorJin Woo Chang-
dc.identifier.doi10.1007/s00701-011-0953-1-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00944-
dc.contributor.localIdA01568-
dc.contributor.localIdA03484-
dc.contributor.localIdA03454-
dc.relation.journalcodeJ00018-
dc.identifier.eissn0942-0940-
dc.identifier.pmid21311918-
dc.identifier.urlhttp://link.springer.com/article/10.1007%2Fs00701-011-0953-1-
dc.subject.keywordDeep brain stimulation-
dc.subject.keywordMicroelectrode recording-
dc.subject.keywordAccuracy-
dc.subject.keywordElectrode positioning-
dc.subject.keywordTargeting-
dc.contributor.alternativeNameKim, Joo Pyung-
dc.contributor.alternativeNamePark, Young Seok-
dc.contributor.alternativeNameChang, Won Seok-
dc.contributor.alternativeNameChang, Jin Woo-
dc.contributor.affiliatedAuthorKim, Joo Pyung-
dc.contributor.affiliatedAuthorPark, Young Seok-
dc.contributor.affiliatedAuthorChang, Jin Woo-
dc.contributor.affiliatedAuthorChang, Won Seok-
dc.rights.accessRightsnot free-
dc.citation.volume153-
dc.citation.number5-
dc.citation.startPage1087-
dc.citation.endPage1095-
dc.identifier.bibliographicCitationACTA NEUROCHIRURGICA, Vol.153(5) : 1087-1095, 2011-
dc.identifier.rimsid27806-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.