4 559

Cited 17 times in

Evaluation of automated serum des-gamma-carboxyprothrombin (DCP) assays for detecting hepatocellular carcinoma

DC Field Value Language
dc.contributor.author김정호-
dc.contributor.author김현숙-
dc.contributor.author박용정-
dc.date.accessioned2014-12-20T17:24:51Z-
dc.date.available2014-12-20T17:24:51Z-
dc.date.issued2011-
dc.identifier.issn0009-9120-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94557-
dc.description.abstractOBJECTIVES: We evaluated two new autoanalyzers, μTAS and Lumipulse for des-γ-carboxyprothrombin (DCP) assay. MATERIAL AND METHODS: Analytical performance was evaluated, and the upper reference limit of the 97.5th percentile for DCP was re-established using sera from 140 healthy individuals. DCP levels were determined by the two autoanalyzers and EIA in a total of 239 sera from HCC patients (n=120) and those without HCC (n=119). RESULTS: Total imprecision of the two automated assays was <5% CV. Analytical measurement ranges (AMRs) were verified to be linear. The new reference limits were 29.5 mAU/mL for μTAS and 35.0 mAU/mL for Lumipulse. There were proportional and constant biases between the results from the autoanalyzers and those from EIA. CONCLUSION: The two newly developed DCP assays showed high analytical performance, but re-establishment of reference limits would be necessary. The new analyzers could be useful for clinical laboratories because of convenience of operation and wide AMRs-
dc.description.statementOfResponsibilityopen-
dc.format.extent1464~1468-
dc.relation.isPartOfCLINICAL BIOCHEMISTRY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAutomation, Laboratory*-
dc.subject.MESHBiomarkers/blood*-
dc.subject.MESHCarcinoma, Hepatocellular/blood-
dc.subject.MESHCarcinoma, Hepatocellular/diagnosis*-
dc.subject.MESHCase-Control Studies-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImmunoassay/methods-
dc.subject.MESHImmunoassay/standards-
dc.subject.MESHLiver Neoplasms/blood-
dc.subject.MESHLiver Neoplasms/diagnosis*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHProtein Precursors/blood*-
dc.subject.MESHProthrombin-
dc.subject.MESHQuality Control-
dc.subject.MESHROC Curve-
dc.subject.MESHReference Standards-
dc.subject.MESHReference Values-
dc.titleEvaluation of automated serum des-gamma-carboxyprothrombin (DCP) assays for detecting hepatocellular carcinoma-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorJonghyeon Choi-
dc.contributor.googleauthorYongjung Park-
dc.contributor.googleauthorJeong-Ho Kim-
dc.contributor.googleauthorHyon-Suk Kim-
dc.identifier.doi10.1016/j.clinbiochem.2011.08.1144-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00903-
dc.contributor.localIdA01582-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ00561-
dc.identifier.eissn1873-2933-
dc.identifier.pmid21939644-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0009912011026324-
dc.subject.keywordDes-γ-carboxyprothrombin (DCP)-
dc.subject.keywordHepatocellular carcinoma (HCC)-
dc.subject.keywordProtein induced by vitamin K absence or antagonist-II (PIVKA-II)-
dc.subject.keywordAutomated analyzer-
dc.subject.keywordReference range-
dc.contributor.alternativeNameKim, Jeong Ho-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.alternativeNamePark, Yong Jung-
dc.contributor.affiliatedAuthorKim, Jeong Ho-
dc.contributor.affiliatedAuthorPark, Yong Jung-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.rights.accessRightsnot free-
dc.citation.volume44-
dc.citation.number17-18-
dc.citation.startPage1464-
dc.citation.endPage1468-
dc.identifier.bibliographicCitationCLINICAL BIOCHEMISTRY, Vol.44(17-18) : 1464-1468, 2011-
dc.identifier.rimsid27416-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.