289 671

Cited 0 times in

Chlamydia trachomatis 검출을 위한 실시간 중합효소연쇄반응법 2종의 평가

DC Field Value Language
dc.contributor.author김신영-
dc.contributor.author김현숙-
dc.date.accessioned2014-12-20T17:15:43Z-
dc.date.available2014-12-20T17:15:43Z-
dc.date.issued2011-
dc.identifier.issn1225-097X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94263-
dc.description.abstractBackgroundChlamydia trachomatis is common etiological agent of sexual transmitted disease. We evaluated two real-time PCR assays for the detection of C. trachomatis; Cobas TaqMan CT test v2.0 (Roche Diagnostics, Switzerland) and AdvanSure CT/NG real-time PCR (LG Life Sciences, Korea). And we compared performance of two real-time PCR assays with Cobas Amplicor CT test (Roche Diagnostics, Switzerland).Methods:Seventy-nine cervical swab specimens collected from patients with suspected C. trachomatis infection were tested using CTM CT, ADVANSURE, and AMPLICOR for the detection of C. trachomatis. Results:Twenty-five (31.6%) samples showed positive results in all three assays. The positive and negative concordance rates among three assays were 100% Conclusion:CTM CT and ADVANSURE showed excellent agreement with AMPLICOR. Therefore, these assays were reliable for the evaluation of C. trachomatis infection.-
dc.description.statementOfResponsibilityopen-
dc.format.extent43~47-
dc.relation.isPartOfJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleChlamydia trachomatis 검출을 위한 실시간 중합효소연쇄반응법 2종의 평가-
dc.title.alternativeEvaluation of two real-time PCR assays for the detection of Chlamydia trachomatis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthor이은영-
dc.contributor.googleauthor김신영-
dc.contributor.googleauthor김현숙-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00675-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ01555-
dc.subject.keywordChlamydia trachomatis-
dc.subject.keywordReal-time polymearse chain reaction-
dc.subject.keywordcomparison-
dc.contributor.alternativeNameKim, Sin Young-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.affiliatedAuthorKim, Sin Young-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.rights.accessRightsfree-
dc.citation.volume33-
dc.citation.number1-
dc.citation.startPage43-
dc.citation.endPage47-
dc.identifier.bibliographicCitationJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리), Vol.33(1) : 43-47, 2011-
dc.identifier.rimsid27501-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.