Evaluation of the i-Smart 30 Point-of-Care Analyzer for Use in Clinical Laboratory Settings

DC Field Value Language
dc.contributor.author권오헌-
dc.contributor.author이운형-
dc.date.accessioned2014-12-20T16:58:26Z-
dc.date.available2014-12-20T16:58:26Z-
dc.date.issued2011-
dc.identifier.issn1225-097X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/93729-
dc.description.abstractBACKGROUND: The i-Smart 30 point-of-care (POC) analyzer (i-SENS, Korea) is a compact and portable system used for the analysis of electrolytes (sodium, potassium, chloride) and hematocrit in whole blood samples. In this study, we evaluated the analytical performance of the i-Smart 30 analyzer. METHODS: Precision and sample-related percent carry-over were determined using the quality control materials. Comparison study was performed with the Stat Profile Critical Care Xpress (STP CCX; Nova Biomedical, USA) analyzer using venous whole blood samples. RESULTS: In the precision study, imprecision studies demonstrated within-run and total-run coefficients of variation within 0.5-3.9% and 0.7-4.4%, respectively, for all analytes. A good correlation was found between the i-Smart 30 analyzer and the STP CCX analyzer, except for chloride that showed high intercept. In the study of carry-over, sample-related carry-over for Na+, K+, Cl- and Hct were demonstrated as 0.84%, 0%, 0.86% and 1.56%, respectively. CONCLUSIONS: We conclude that the i-Smart 30 analyzer is suitable for routine use in clinical laboratories, especially where rapid test results are required such as emergency departments, intensive care units, and dialysis units. However, for Cl-, it is necessary that a significant correlation between this analyzer and a reference method should be demonstrated.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleEvaluation of the i-Smart 30 Point-of-Care Analyzer for Use in Clinical Laboratory Settings-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorSeok Y-
dc.contributor.googleauthorLee W-
dc.contributor.googleauthorYoon S-
dc.contributor.googleauthorWon Y-
dc.contributor.googleauthorKwon OH-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00237-
dc.contributor.localIdA02997-
dc.relation.journalcodeJ01555-
dc.contributor.alternativeNameKwon, Oh Hun-
dc.contributor.alternativeNameLee, Woon Hyoung-
dc.contributor.affiliatedAuthorKwon, Oh Hun-
dc.contributor.affiliatedAuthorLee, Woon Hyoung-
dc.rights.accessRightsfree-
dc.citation.volume33-
dc.citation.number1-
dc.citation.startPage25-
dc.citation.endPage30-
dc.identifier.bibliographicCitationJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리), Vol.33(1) : 25-30, 2011-
dc.identifier.rimsid28422-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.