Cited 57 times in
Robotic single-port transumbilical total hysterectomy: a pilot study.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김상운 | - |
dc.contributor.author | 김성훈 | - |
dc.contributor.author | 김영태 | - |
dc.contributor.author | 김재욱 | - |
dc.contributor.author | 김재훈 | - |
dc.contributor.author | 남은지 | - |
dc.contributor.author | 백지흠 | - |
dc.contributor.author | 이마리아 | - |
dc.contributor.author | 이산희 | - |
dc.contributor.author | 임가원 | - |
dc.date.accessioned | 2014-12-20T16:49:44Z | - |
dc.date.available | 2014-12-20T16:49:44Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 2005-0380 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/93455 | - |
dc.description.abstract | OBJECTIVE: To evaluate the feasibility of robotic single-port transumbilical total hysterectomy using a home-made surgical glove port system. METHODS: We retrospectively reviewed the medical records of patients who underwent robotic single-port transumbilical total hysterectomy between January 2010 and July 2010. All surgical procedures were performed through a single 3-4-cm umbilical incision, with a multi-channel system consisting of a wound retractor, a surgical glove, and two 10/12-mm and two 8 mm trocars. RESULTS: Seven patients were treated with robotic single-port transumbilical total hysterectomy. Procedures included total hysterectomy due to benign gynecological disease (n=5), extra-fascial hysterectomy due to carcinoma in situ of the cervix (n=1), and radical hysterectomy due to cervical cancer IB1 (n=1). The median total operative time was 109 minutes (range, 105 to 311 minutes), the median blood loss was 100 mL (range, 10 to 750 mL), and the median weight of the resected uteri was 200 g (range, 40 to 310 g). One benign case was converted to 3-port robotic surgery due to severe pelvic adhesions, and no post-operative complications occurred. CONCLUSION: Robotic single-port transumbilical total hysterectomy is technically feasible in selected patients with gynecological disease. Robotics may enhance surgical skills during single-port transumbilical hysterectomy, especially in patients with gynecologic cancers. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 120~126 | - |
dc.relation.isPartOf | JOURNAL OF GYNECOLOGIC ONCOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Robotic single-port transumbilical total hysterectomy: a pilot study. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Obstetrics & Gynecology (산부인과학) | - |
dc.contributor.googleauthor | Eun Ji Nam | - |
dc.contributor.googleauthor | Sang Wun Kim | - |
dc.contributor.googleauthor | Maria Lee | - |
dc.contributor.googleauthor | Ga Won Yim | - |
dc.contributor.googleauthor | Ji Heum Paek | - |
dc.contributor.googleauthor | San Hui Lee | - |
dc.contributor.googleauthor | Sunghoon Kim | - |
dc.contributor.googleauthor | Jae Hoon Kim | - |
dc.contributor.googleauthor | Jae Wook Kim | - |
dc.contributor.googleauthor | Young Tae Kim | - |
dc.identifier.doi | 10.3802/jgo.2011.22.2.120 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00595 | - |
dc.contributor.localId | A00866 | - |
dc.contributor.localId | A00526 | - |
dc.contributor.localId | A00729 | - |
dc.contributor.localId | A00876 | - |
dc.contributor.localId | A01262 | - |
dc.contributor.localId | A01840 | - |
dc.contributor.localId | A02748 | - |
dc.contributor.localId | A02808 | - |
dc.contributor.localId | A03354 | - |
dc.relation.journalcode | J01428 | - |
dc.identifier.eissn | 2005-0399 | - |
dc.identifier.pmid | 21860738 | - |
dc.subject.keyword | Robotic surgery | - |
dc.subject.keyword | Single-port | - |
dc.subject.keyword | Laparoscopic | - |
dc.subject.keyword | Hysterectomy | - |
dc.subject.keyword | Gynecology | - |
dc.contributor.alternativeName | Kim, Sang Wun | - |
dc.contributor.alternativeName | Kim, Sung Hoon | - |
dc.contributor.alternativeName | Kim, Young Tae | - |
dc.contributor.alternativeName | Kim, Jae Wook | - |
dc.contributor.alternativeName | Kim, Jae Hoon | - |
dc.contributor.alternativeName | Nam, Eun Ji | - |
dc.contributor.alternativeName | Paek, Ji Heum | - |
dc.contributor.alternativeName | Lee, Maria | - |
dc.contributor.alternativeName | Lee, San Hui | - |
dc.contributor.alternativeName | Yim, Ga Won | - |
dc.contributor.affiliatedAuthor | Kim, Sung Hoon | - |
dc.contributor.affiliatedAuthor | Kim, Jae Wook | - |
dc.contributor.affiliatedAuthor | Kim, Sang Wun | - |
dc.contributor.affiliatedAuthor | Kim, Young Tae | - |
dc.contributor.affiliatedAuthor | Kim, Jae Hoon | - |
dc.contributor.affiliatedAuthor | Nam, Eun Ji | - |
dc.contributor.affiliatedAuthor | Paek, Ji Heum | - |
dc.contributor.affiliatedAuthor | Lee, Maria | - |
dc.contributor.affiliatedAuthor | Lee, San Hui | - |
dc.contributor.affiliatedAuthor | Yim, Ga Won | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 22 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 120 | - |
dc.citation.endPage | 126 | - |
dc.identifier.bibliographicCitation | JOURNAL OF GYNECOLOGIC ONCOLOGY, Vol.22(2) : 120-126, 2011 | - |
dc.identifier.rimsid | 28245 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.