3 523

Cited 109 times in

Optimization of phosphatase- and redox cycling-based immunosensors and its application to ultrasensitive detection of troponin I.

DC Field Value Language
dc.contributor.author김신영-
dc.date.accessioned2014-12-20T16:42:46Z-
dc.date.available2014-12-20T16:42:46Z-
dc.date.issued2011-
dc.identifier.issn0003-2700-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/93234-
dc.description.abstractThe authors herein report optimized conditions for ultrasensitive phosphatase-based immunosensors (using redox cycling by a reducing agent) that can be simply prepared and readily applied to microfabricated electrodes. The optimized conditions were applied to the ultrasensitive detection of cardiac troponin I in human serum. The preparation of an immunosensing layer was based on passive adsorption of avidin (in carbonate buffer (pH 9.6)) onto indium-tin oxide (ITO) electrodes. The immunosensing layer allows very low levels of nonspecific binding of proteins. The optimum conditions for the enzymatic reaction were investigated in terms of the type of buffer solution, temperature, and concentration of MgCl(2), and the optimum conditions for antigen-antibody binding were determined in terms of incubation time, temperature, and concentration of phosphatase-conjugated IgG. Very importantly, the antigen-antibody binding at 4 °C is extremely important in obtaining reproducible results. Among the four phosphatase substrates (L-ascorbic acid 2-phosphate (AAP), 4-aminophenyl phosphate, 1-naphthyl phosphate, 4-amino-1-naphthyl phosphate) and four phosphatase products (L-ascorbic acid (AA), 4-aminophenol, 1-naphthol, 4-amino-1-naphthol), AAP and AA meet the requirements most for obtaining easy dissolution and high signal-to-background ratios. More importantly, fast AA electrooxidation at the ITO electrodes does not require modification with any electrocatalyst or electron mediator. Furthermore, tris(2-carboxyethyl)phosphine (TCEP) as a reducing agent allows fast redox cycling, along with very low anodic currents at the ITO electrodes. Under these optimized conditions, the detection limit of an immunosensor for troponin I obtained without redox cycling of AA by TCEP is ca. 100 fg/mL, and with redox cycling it is ca. 10 fg/mL. A detection limit of 10 fg/mL was also obtained even when an immunosensing layer was simply formed on a micropatterned ITO electrode. From a practical point of view, it is of great importance that ultralow detection limits can be obtained with simply prepared enzyme-based immunosensors.-
dc.description.statementOfResponsibilityopen-
dc.format.extent3926~3933-
dc.relation.isPartOfANALYTICAL CHEMISTRY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAlkaline Phosphatase/chemistry-
dc.subject.MESHAlkaline Phosphatase/metabolism-
dc.subject.MESHAntibodies/immunology-
dc.subject.MESHAvidin/chemistry-
dc.subject.MESHBiosensing Techniques/methods*-
dc.subject.MESHElectrochemical Techniques/methods-
dc.subject.MESHElectrodes-
dc.subject.MESHHumans-
dc.subject.MESHImmunoassay/methods*-
dc.subject.MESHMagnesium Chloride/chemistry-
dc.subject.MESHOxidation-Reduction-
dc.subject.MESHPhosphoric Monoester Hydrolases/chemistry-
dc.subject.MESHPhosphoric Monoester Hydrolases/metabolism*-
dc.subject.MESHTemperature-
dc.subject.MESHTin Compounds/chemistry-
dc.subject.MESHTroponin I/blood*-
dc.titleOptimization of phosphatase- and redox cycling-based immunosensors and its application to ultrasensitive detection of troponin I.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorMd. Rajibul Akanda-
dc.contributor.googleauthorMd. Abdul Aziz-
dc.contributor.googleauthorKyungmin Jo-
dc.contributor.googleauthorVellaiappillai Tamilavan-
dc.contributor.googleauthorMyung Ho Hyun-
dc.contributor.googleauthorSinyoung Kim-
dc.contributor.googleauthorHaesik Yang-
dc.identifier.doi10.1021/ac200447b-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00675-
dc.relation.journalcodeJ00136-
dc.identifier.eissn1520-6882-
dc.identifier.pmid21486093-
dc.identifier.urlhttp://pubs.acs.org/doi/full/10.1021/ac200447b-
dc.contributor.alternativeNameKim, Sin Young-
dc.contributor.affiliatedAuthorKim, Sin Young-
dc.rights.accessRightsnot free-
dc.citation.volume83-
dc.citation.number10-
dc.citation.startPage3926-
dc.citation.endPage3933-
dc.identifier.bibliographicCitationANALYTICAL CHEMISTRY, Vol.83(10) : 3926-3933, 2011-
dc.identifier.rimsid27077-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.