Cited 126 times in
CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김화선 | - |
dc.contributor.author | 남지은 | - |
dc.contributor.author | 이상민 | - |
dc.contributor.author | 이혜정 | - |
dc.contributor.author | 최규옥 | - |
dc.contributor.author | 최병욱 | - |
dc.contributor.author | 허진 | - |
dc.contributor.author | 홍유진 | - |
dc.contributor.author | 김가람 | - |
dc.contributor.author | 김영진 | - |
dc.contributor.author | 김태훈 | - |
dc.date.accessioned | 2014-12-20T16:38:50Z | - |
dc.date.available | 2014-12-20T16:38:50Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 0938-7994 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/93110 | - |
dc.description.abstract | OBJECTIVE: We evaluated radiation doses, complication rates, and diagnostic accuracy for CT-guided percutaneous needle aspiration biopsy (NAB) procedures of pulmonary lesions performed with or without fluoroscopic guidance. METHODS: A total of 142 patients were prospectively enrolled to receive CT-guided NAB with (Group I, n = 72) or without (Group II, n = 70) fluoroscopic guidance. Outcome measurements were patient and doctor radiation dose, and complication rate. Sensitivity, specificity and accuracy were calculated based on 123 NAB results. RESULTS: The mean estimated effective patient radiation dose was 6.53 mSv in Group I and 2.72 mSv in Group II (p < 0.001). The mean estimated effective doctor dose was 0.054 mSv in Group I and 0.029 mSv in Group II (p < 0.001). The complication rate was significantly different between the two groups (13.4% versus 31.4%, p = 0.012). Sensitivity, specificity and accuracy for diagnosing pulmonary lesions were 97.8%, 100% and 98.4% in group I and 95.3%, 100% and 89.5% in group II (p > 0.05). CONCLUSIONS: CT fluoroscopy-guided NAB of pulmonary lesions provides high diagnostic accuracy and can be performed with significantly fewer complications. However, radiation exposure to both patient and doctor were significantly higher than conventional CT-guided NAB. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 232~239 | - |
dc.relation.isPartOf | EUROPEAN RADIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Biopsy, Needle/statistics & numerical data* | - |
dc.subject.MESH | Comorbidity | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Incidence | - |
dc.subject.MESH | Lung Neoplasms/diagnosis* | - |
dc.subject.MESH | Lung Neoplasms/epidemiology* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Postoperative Complications/epidemiology* | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Radiation Dosage* | - |
dc.subject.MESH | Radiography, Interventional/statistics & numerical data* | - |
dc.subject.MESH | Radiometry/statistics & numerical data | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Republic of Korea/epidemiology | - |
dc.subject.MESH | Risk Assessment/methods | - |
dc.subject.MESH | Risk Factors | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Tomography, X-Ray Computed/statistics & numerical data* | - |
dc.title | CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Ga Ram Kim | - |
dc.contributor.googleauthor | Jin Hur | - |
dc.contributor.googleauthor | Sang Min Lee | - |
dc.contributor.googleauthor | Hye-Jeong Lee | - |
dc.contributor.googleauthor | Yoo Jin Hong | - |
dc.contributor.googleauthor | Ji Eun Nam | - |
dc.contributor.googleauthor | Hua Sun Kim | - |
dc.contributor.googleauthor | Young Jin Kim | - |
dc.contributor.googleauthor | Byoung Wook Choi | - |
dc.contributor.googleauthor | Tae Hoon Kim | - |
dc.contributor.googleauthor | Kyu Ok Choe | - |
dc.identifier.doi | 10.1007/s00330-010-1936-y | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00727 | - |
dc.contributor.localId | A03320 | - |
dc.contributor.localId | A01086 | - |
dc.contributor.localId | A02815 | - |
dc.contributor.localId | A01196 | - |
dc.contributor.localId | A01269 | - |
dc.contributor.localId | A04042 | - |
dc.contributor.localId | A04059 | - |
dc.contributor.localId | A04370 | - |
dc.contributor.localId | A04422 | - |
dc.contributor.localId | A00284 | - |
dc.relation.journalcode | J00851 | - |
dc.identifier.eissn | 1432-1084 | - |
dc.identifier.pmid | 20730613 | - |
dc.identifier.url | http://link.springer.com/article/10.1007%2Fs00330-010-1936-y | - |
dc.subject.keyword | Computed tomography (CT) | - |
dc.subject.keyword | CT fluoroscopy | - |
dc.subject.keyword | Percutaneous needle aspiration biopsy | - |
dc.subject.keyword | Radiation dose | - |
dc.subject.keyword | Pulmonary nodules. | - |
dc.contributor.alternativeName | Kim, Hua Sun | - |
dc.contributor.alternativeName | Nam, Ji Eun | - |
dc.contributor.alternativeName | Lee, Sang Min | - |
dc.contributor.alternativeName | Lee, Hye Jeong | - |
dc.contributor.alternativeName | Choe, Kyu Ok | - |
dc.contributor.alternativeName | Choi, Byoung Wook | - |
dc.contributor.alternativeName | Hur, Jin | - |
dc.contributor.alternativeName | Hong, Yoo Jin | - |
dc.contributor.alternativeName | Kim, Ga Ram | - |
dc.contributor.alternativeName | Kim, Young Jin | - |
dc.contributor.alternativeName | Kim, Tae Hoon | - |
dc.contributor.affiliatedAuthor | Kim, Young Jin | - |
dc.contributor.affiliatedAuthor | Lee, Hye Jeong | - |
dc.contributor.affiliatedAuthor | Kim, Tae Hoon | - |
dc.contributor.affiliatedAuthor | Lee, Sang Min | - |
dc.contributor.affiliatedAuthor | Kim, Hua Sun | - |
dc.contributor.affiliatedAuthor | Nam, Ji Eun | - |
dc.contributor.affiliatedAuthor | Choe, Kyu Ok | - |
dc.contributor.affiliatedAuthor | Choi, Byoung Wook | - |
dc.contributor.affiliatedAuthor | Hur, Jin | - |
dc.contributor.affiliatedAuthor | Hong, Yoo Jin | - |
dc.contributor.affiliatedAuthor | Kim, Ga Ram | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 21 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 232 | - |
dc.citation.endPage | 239 | - |
dc.identifier.bibliographicCitation | EUROPEAN RADIOLOGY, Vol.21(2) : 232-239, 2011 | - |
dc.identifier.rimsid | 28033 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.