Cited 27 times in
Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김윤재 | - |
dc.contributor.author | 김희만 | - |
dc.contributor.author | 박승우 | - |
dc.contributor.author | 박정엽 | - |
dc.contributor.author | 방승민 | - |
dc.contributor.author | 송시영 | - |
dc.contributor.author | 전태주 | - |
dc.contributor.author | 정재복 | - |
dc.contributor.author | 조재희 | - |
dc.date.accessioned | 2014-12-20T16:26:35Z | - |
dc.date.available | 2014-12-20T16:26:35Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 0930-2794 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92725 | - |
dc.description.abstract | BACKGROUND: The self-expandable metallic stent (SEMS) has been widely used for unresectable malignant biliary obstruction but eventually becomes occluded by tumor ingrowth/overgrowth and sludge. Therefore, we aimed to determine the therapeutic effectiveness of secondary stents and to find differences according to various combinations of the first and second stents for the management of occluded SEMSs in patients with malignant distal biliary obstruction. METHODS: Between 1999 and November 2008, 77 patients with malignant biliary obstruction underwent secondary biliary stent placement as "stent-in-stent" at three university hospitals in Korea (40 covered, 26 uncovered, and 11 plastic stents). The membrane of the covered SEMS was regarded as the barrier against tumor ingrowth. We categorized the patients into three groups based on whether the covered SEMS was either the first or the second stent: membrane-SEMS (18 covered-covered; 9 covered-uncovered; 22 uncovered-covered SEMS), bare-SEMS (17 uncovered-uncovered SEMS), and plastic stent (3 covered-plastic; 8 uncovered-plastic). RESULTS: The median patency of second stents was 138, 109, and 88 days (covered, uncovered, and plastic stents). The second covered SEMSs had a significantly longer patency than plastic stents (p=0.047). In a multivariate analysis including membrane-SEMS, bare-SEMS, and plastic stent groups, the bare-SEMS had a worse cumulative stent patency (HR=2.04, CI=1.08-3.86) and survival time (HR=2.37, CI=1.25-4.49) than the membrane-SEMS. Patients with ampulla of Vater cancer had better stent patency (HR=0.27, CI=0.08-0.98) and survival (HR=0.17, CI=0.04-0.77) than those with other pancreatobiliary malignancies. In addition, antitumor treatment prolonged survival time (HR=0.50, CI=0.26-0.99). CONCLUSIONS: The placement of additional biliary stents using the "stent-in-stent" method is an effective treatment for an occluded metallic primary stent. In addition, double biliary SEMS placement using at least one covered SEMS (in the primary and/or secondary procedure) might provide longer cumulative stent patency and survival than using uncovered SEMSs in both procedures. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 475~482 | - |
dc.relation.isPartOf | SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Biliary Tract Neoplasms/complications | - |
dc.subject.MESH | Biliary Tract Neoplasms/pathology* | - |
dc.subject.MESH | Cholestasis, Intrahepatic/mortality | - |
dc.subject.MESH | Cholestasis, Intrahepatic/pathology* | - |
dc.subject.MESH | Cholestasis, Intrahepatic/surgery* | - |
dc.subject.MESH | Coated Materials, Biocompatible | - |
dc.subject.MESH | Cohort Studies | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Follow-Up Studies | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Kaplan-Meier Estimate | - |
dc.subject.MESH | Metals | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Neoplasm Staging | - |
dc.subject.MESH | Palliative Care/methods | - |
dc.subject.MESH | Plastics | - |
dc.subject.MESH | Proportional Hazards Models | - |
dc.subject.MESH | Prosthesis Design | - |
dc.subject.MESH | Prosthesis Failure | - |
dc.subject.MESH | Prosthesis Implantation/methods* | - |
dc.subject.MESH | Reoperation | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Risk Assessment | - |
dc.subject.MESH | Stents* | - |
dc.subject.MESH | Survival Analysis | - |
dc.subject.MESH | Time Factors | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Jae Hee Cho | - |
dc.contributor.googleauthor | Tae Joo Jeon | - |
dc.contributor.googleauthor | Jeong Youp Park | - |
dc.contributor.googleauthor | Hee Man Kim | - |
dc.contributor.googleauthor | Yoon Jae Kim | - |
dc.contributor.googleauthor | Seung Woo Park | - |
dc.contributor.googleauthor | Jae Bock Chung | - |
dc.contributor.googleauthor | Si Young Song | - |
dc.contributor.googleauthor | Seungmin Bang | - |
dc.identifier.doi | 10.1007/s00464-010-1196-6 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00792 | - |
dc.contributor.localId | A01210 | - |
dc.contributor.localId | A01551 | - |
dc.contributor.localId | A01647 | - |
dc.contributor.localId | A01786 | - |
dc.contributor.localId | A02035 | - |
dc.contributor.localId | A03706 | - |
dc.contributor.localId | A03902 | - |
dc.contributor.localId | A03557 | - |
dc.relation.journalcode | J02703 | - |
dc.identifier.eissn | 1432-2218 | - |
dc.identifier.pmid | 20602138 | - |
dc.identifier.url | http://link.springer.com/article/10.1007%2Fs00464-010-1196-6 | - |
dc.subject.keyword | Malignant biliary obstruction | - |
dc.subject.keyword | Self-expandable metallic stent | - |
dc.subject.keyword | Plastic stent | - |
dc.subject.keyword | Occlusion | - |
dc.subject.keyword | Stent patency | - |
dc.subject.keyword | Survival | - |
dc.contributor.alternativeName | Kim, Yoon Jae | - |
dc.contributor.alternativeName | Kim, Hee Man | - |
dc.contributor.alternativeName | Park, Seung Woo | - |
dc.contributor.alternativeName | Park, Jeong Youp | - |
dc.contributor.alternativeName | Bang, Seung Min | - |
dc.contributor.alternativeName | Song, Si Young | - |
dc.contributor.alternativeName | Jeon, Tae Joo | - |
dc.contributor.alternativeName | Chung, Jae Bock | - |
dc.contributor.alternativeName | Cho, Jae Hee | - |
dc.contributor.affiliatedAuthor | Kim, Yoon Jae | - |
dc.contributor.affiliatedAuthor | Kim, Hee Man | - |
dc.contributor.affiliatedAuthor | Park, Seung Woo | - |
dc.contributor.affiliatedAuthor | Park, Jeong Youp | - |
dc.contributor.affiliatedAuthor | Bang, Seung Min | - |
dc.contributor.affiliatedAuthor | Song, Si Young | - |
dc.contributor.affiliatedAuthor | Chung, Jae Bock | - |
dc.contributor.affiliatedAuthor | Cho, Jae Hee | - |
dc.contributor.affiliatedAuthor | Jeon, Tae Joo | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 25 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 475 | - |
dc.citation.endPage | 482 | - |
dc.identifier.bibliographicCitation | SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, Vol.25(2) : 475-482, 2011 | - |
dc.identifier.rimsid | 28720 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.