Cited 27 times in
Comparison of optical coherence tomographic assessment between first- and second-generation drug-eluting stents
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 홍명기 | - |
dc.contributor.author | 고영국 | - |
dc.contributor.author | 김병극 | - |
dc.contributor.author | 김중선 | - |
dc.contributor.author | 박준범 | - |
dc.contributor.author | 장양수 | - |
dc.date.accessioned | 2014-12-19T17:47:53Z | - |
dc.date.available | 2014-12-19T17:47:53Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 0513-5796 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92078 | - |
dc.description.abstract | PURPOSE: There is a lack of sufficient data in comparison of optical coherence tomographic (OCT) findings between first- and second-generation drug-eluting stents (DES). Compared to first-generation (i.e., sirolimus- or paclitaxel-eluting stents), second-generation DESs (i.e., everolimus- or biolinx-based zotarolimus-eluting stents) might have more favorable neointimal coverage. MATERIALS AND METHODS: Follow-up OCT findings of 103 patients (119 lesions) treated with second- generation DESs were compared with those of 139 patients (149 lesions) treated with first-generation DESs. The percentage of uncovered or malapposed struts, calculated as the ratio of uncovered or malapposed struts to total struts in all OCT cross-sections, respectively, was compared between the two groups. RESULTS: Both DES groups showed similar suppression of neointimal hyperplasia (NIH) on OCT (mean NIH cross-sectional area; second- vs. first-generation=1.1±0.5 versus 1.2±1.0 mm², respectively, p=0.547). However, the percentage of uncovered struts of second-generation DESs was significantly smaller than that of first-generation DESs (3.8±4.8% vs.7.5±11.1%, respectively, p<0.001). The percentage of malapposed struts was also significantly smaller in second-generation DESs than in first-generation DESs (0.4±1.6% vs.1.4±3.7%, respectively, p=0.005). In addition, intra- stent thrombi were less frequently detected in second-generations DESs than in first-generation DESs (8% vs. 20%, respectively, p=0.004). CONCLUSION: This follow-up OCT study showed that second-generation DESs characteristically had greater neointimal coverage than first-generation DESs. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.relation.isPartOf | YONSEI MEDICAL JOURNAL | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Coronary Angiography | - |
dc.subject.MESH | Drug-Eluting Stents* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Neointima/pathology | - |
dc.subject.MESH | Neointima/prevention & control | - |
dc.subject.MESH | Tomography, Optical Coherence/methods* | - |
dc.title | Comparison of optical coherence tomographic assessment between first- and second-generation drug-eluting stents | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Byeong-Keuk Kim | - |
dc.contributor.googleauthor | Jung-Sun Kim | - |
dc.contributor.googleauthor | Junbeom Park | - |
dc.contributor.googleauthor | Young-Guk Ko | - |
dc.contributor.googleauthor | Donghoon Choi | - |
dc.contributor.googleauthor | Yangsoo Jang | - |
dc.contributor.googleauthor | Myeong-Ki Hong | - |
dc.identifier.doi | 10.3349/ymj.2012.53.3.524 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A04391 | - |
dc.contributor.localId | A00127 | - |
dc.contributor.localId | A00493 | - |
dc.contributor.localId | A00961 | - |
dc.contributor.localId | A01670 | - |
dc.contributor.localId | A03448 | - |
dc.relation.journalcode | J02813 | - |
dc.identifier.eissn | 1976-2437 | - |
dc.identifier.pmid | 22476995 | - |
dc.subject.keyword | Optical coherence tomography | - |
dc.subject.keyword | stent | - |
dc.contributor.alternativeName | Choi, Dong Hoon | - |
dc.contributor.alternativeName | Hong, Myeong Ki | - |
dc.contributor.alternativeName | Ko, Young Guk | - |
dc.contributor.alternativeName | Kim, Byeong Keuk | - |
dc.contributor.alternativeName | Kim, Jung Sun | - |
dc.contributor.alternativeName | Park, Jun Beom | - |
dc.contributor.alternativeName | Jang, Yang Soo | - |
dc.contributor.affiliatedAuthor | Choi, Dong Hoon | - |
dc.contributor.affiliatedAuthor | Hong, Myeong Ki | - |
dc.contributor.affiliatedAuthor | Ko, Young Guk | - |
dc.contributor.affiliatedAuthor | Kim, Byeong Keuk | - |
dc.contributor.affiliatedAuthor | Kim, Jung Sun | - |
dc.contributor.affiliatedAuthor | Park, Jun Beom | - |
dc.contributor.affiliatedAuthor | Jang, Yang Soo | - |
dc.citation.volume | 53 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 524 | - |
dc.citation.endPage | 529 | - |
dc.identifier.bibliographicCitation | YONSEI MEDICAL JOURNAL, Vol.53(3) : 524-529, 2012 | - |
dc.identifier.rimsid | 29598 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.