Cited 1 times in

Effect of using a titanium washer on the removal torque of an abutment screw in the external connection type of dental implant

DC Field Value Language
dc.contributor.author심준성-
dc.contributor.author이근우-
dc.date.accessioned2014-12-19T16:53:39Z-
dc.date.available2014-12-19T16:53:39Z-
dc.date.issued2012-
dc.identifier.issn1056-6163-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/90392-
dc.description.abstractPURPOSE: The aim of this study was to determine the effect of using a washer on the removal torque of an abutment screw in the external connection type of dental implant and abutment complex. MATERIALS AND METHODS: Four experimental groups with titanium washers of different types (CP titanium or Ti6Al4V titanium alloy) and thicknesses (1.0 or 2.0 mm) included between the abutment and external connection type of implant were investigated. No washer was applied in the control group. The removal torque was measured with a resolution of 0.1 Ncm. One-way analysis of variance (α = 0.05) and Scheffé's post hoc test were used for statistical analysis. RESULTS: The removal torque was higher in all the groups with a washer than in the control group (α = 0.05), higher with a CP titanium washer than with a titanium alloy washer of the same thickness, and higher with a 2.0-mm-thick washer than with a 1.0-mm-thick washer (α = 0.05). CONCLUSIONS: Inclusion of a washer between the titanium screw and the abutment seems to increase the removal torque. A 2.0-mm-thick CP titanium washer might provide the largest increase in the removal torque.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfIMPLANT DENTISTRY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHDental Abutments*-
dc.subject.MESHDental Alloys/chemistry-
dc.subject.MESHDental Implant-Abutment Design/instrumentation*-
dc.subject.MESHDental Materials/chemistry*-
dc.subject.MESHDental Prosthesis Design*-
dc.subject.MESHElastic Modulus-
dc.subject.MESHHumans-
dc.subject.MESHMaterials Testing-
dc.subject.MESHPliability-
dc.subject.MESHSurface Properties-
dc.subject.MESHTitanium/chemistry*-
dc.subject.MESHTorque-
dc.titleEffect of using a titanium washer on the removal torque of an abutment screw in the external connection type of dental implant-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학)-
dc.contributor.googleauthorJamiyandorj, Otgonbold-
dc.contributor.googleauthorKim, Sungtae-
dc.contributor.googleauthorShim, June-Sung-
dc.contributor.googleauthorLee, Keun-Woo-
dc.identifier.doi10.1097/ID.0b013e31824a02b9-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02211-
dc.contributor.localIdA02688-
dc.relation.journalcodeJ01041-
dc.identifier.eissn1538-2982-
dc.identifier.pmid22391862-
dc.identifier.urlhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&AN=00008505-201204000-00015&LSLINK=80&D=ovft-
dc.subject.keywordimplant-
dc.subject.keywordabutmentscrew-
dc.subject.keywordwasher-
dc.subject.keywordthickness-
dc.subject.keywordremoval-
dc.contributor.alternativeNameShim, June Sung-
dc.contributor.alternativeNameLee, Keun Woo-
dc.contributor.affiliatedAuthorShim, June Sung-
dc.contributor.affiliatedAuthorLee, Keun Woo-
dc.citation.volume21-
dc.citation.number2-
dc.citation.startPage156-
dc.citation.endPage159-
dc.identifier.bibliographicCitationIMPLANT DENTISTRY, Vol.21(2) : 156-159, 2012-
dc.identifier.rimsid34186-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.