Comparison of automated multiplexed bead-based ANA screening assay with ELISA for detecting five common anti-extractable nuclear antigens and anti-dsDNA in systemic rheumatic diseases.

DC Field Value Language
dc.contributor.author김현숙-
dc.contributor.author박용정-
dc.date.accessioned2014-12-19T16:40:21Z-
dc.date.available2014-12-19T16:40:21Z-
dc.date.issued2012-
dc.identifier.issn0009-8981-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/89971-
dc.description.abstractBACKGROUND: A newly developed and totally automated Luminex-based assay, the BioPlex™ 2200 system, is able to detect various autoantibodies simultaneously from a single sample. We compared the BioPlex™ 2200 system with ELISA for the detection of six autoantibodies. METHODS: A total of 127 serum samples from the patients with systemic rheumatic diseases were collected and assayed with the BioPlex™ 2200 system (Bio-Rad, USA) and conventional ELISA (INOVA Diagnostics, USA) for 5 anti-extractable nuclear antigens. Additionally, relative sensitivity of the BioPlex™ 2200 system for detecting anti-dsDNA was evaluated with 79 specimens from SLE patients, which were positive for anti-dsDNA by ELISA. RESULTS: The concordance rates between ELISA and the BioPlex ranged from 88.1% for anti-RNP to 95.2% for anti-Scl-70, and the kappa coefficients between the results by the two assays were from 0.48 to 0.67. Among the 79 anti-dsDNA positive specimens by ELISA, seventy-eight (98.7%) showed positive results for anti-dsDNA by the BioPlex. CONCLUSIONS: The BioPlex™ 2200 system showed comparable results with those by conventional ELISA for detecting autoantibodies, and this automated assay could measure multifarious autoantibodies concurrently in a single sample. It could be effectively used in clinical laboratories for screening autoimmune diseases.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfCLINICA CHIMICA ACTA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAntigens, Nuclear/analysis*-
dc.subject.MESHAutomation*-
dc.subject.MESHDNA/immunology*-
dc.subject.MESHEnzyme-Linked Immunosorbent Assay/methods*-
dc.subject.MESHHumans-
dc.subject.MESHMicroscopy, Fluorescence-
dc.subject.MESHRheumatic Diseases/immunology*-
dc.titleComparison of automated multiplexed bead-based ANA screening assay with ELISA for detecting five common anti-extractable nuclear antigens and anti-dsDNA in systemic rheumatic diseases.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorYoonjung Kim-
dc.contributor.googleauthorYongjung Park-
dc.contributor.googleauthorEun Young Lee-
dc.contributor.googleauthorHyon-Suk Kim-
dc.identifier.doi22027339-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01582-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ00543-
dc.identifier.eissn1873-3492-
dc.identifier.pmid22027339-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S000989811100578X-
dc.subject.keywordMultiplex bead-based assay-
dc.subject.keywordBioPlex™ 2200 system-
dc.subject.keywordAutoantibodies-
dc.subject.keywordSystemic lupus erythematosus-
dc.subject.keywordSjögren syndrome-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.alternativeNamePark, Yong Jung-
dc.contributor.affiliatedAuthorPark, Yong Jung-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.citation.volume413-
dc.citation.number1-2-
dc.citation.startPage308-
dc.citation.endPage311-
dc.identifier.bibliographicCitationCLINICA CHIMICA ACTA, Vol.413(1-2) : 308-311, 2012-
dc.identifier.rimsid32010-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.